نتایج جستجو برای: spine fixation

تعداد نتایج: 103101  

2012
Federico De Iure Michele Cappuccio Stefania Paderni Giuseppe Bosco Luca Amendola

We studied 122 patients with 163 fractures of the thoracic and lumbar spine undergoing the surgical treatment by percutaneous transpedicular fixation and stabilization with minimally invasive technique. Patient followup ranged from 6 to 72 months (mean 38 months), and the patients were assessed by clinical and radiographic evaluation. The results show that percutaneous transpedicular fixation a...

2016
Varun Chouhan

INTRODUCTION Arthroscopic fixation of tibial spine fracture in patients with open physis without damaging the growth plate is very important. We have described a very simple and effective technique for the first time in this article. CASE REPORT A 16-year-old boy sustained avulsion fractures of tibial spine while playing. He was treated arthroscopically with excellent results. CONCLUSION Ar...

2016
Nihat Demirhan Demirkiran Olcay Akdeniz Onur Hapa Hasan Havıtçıoğlu

INTRODUCTION Arthroscopic fixation of tibial spine fracture without damage to the growth plate is very important in patients with open physis. The present article describes a simple and effective technique being used for the first time to treat this condition. CASE REPORT A 16-year-old boy sustained avulsion fractures of tibial spine while playing. He was treated arthroscopically with excelle...

Journal: :The Journal of the American Academy of Orthopaedic Surgeons 2007
Christopher M Bono

The halo fixator may be used for the definitive treatment of cervical spine trauma, preoperative reduction in the patient with spinal deformity, and adjunctive postoperative stabilization following cervical spine surgery. Halo fixation decreases cervical motion by 30% to 96%. Absolute contraindications include cranial fracture, infection, and severe soft-tissue injury at the proposed pin sites....

2017
Fei Guo Jianhao Dai Junxiang Zhang Yichuan Ma Guanghui Zhu Junjie Shen Guoqi Niu

PURPOSE Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. METHODS Using CT thin slices da...

2013
Ahmet Levent Aydın Mehdi Sasani

Boucher was the first to use screws that crossed through the strongest point of attachment of the facet joint into the pedicle and the body of the vertebra below. He declared a pseudorthrosis rate of 14% to 17% including multilevel fusions (1). The use of pedicle screw–assisted spinal stabilization has become increasingly popular worldwide. Pedicle screw systems engage all three columns of the ...

Journal: :Journal of spinal disorders 1994
K Abumi H Itoh H Taneichi K Kaneda

Thirteen patients with fractures and/or dislocations of the middle and lower cervical spine were treated by transpedicular screw fixation using the Steffee variable screw placement system. Postoperative immobilization was either not used or simplified to short-term use of a soft neck collar. Recovery of nerve function and correction of kyphotic and/or translational deformities were satisfactory...

Journal: :Orthopedics 2016
Alan H Daniels J Mason DePasse Adam E M Eltorai Mark A Palumbo

Iliac fixation is indicated to provide spinopelvic stabilization in select cases of long segment thoracolumbar spine fusion, spinal osteotomy/realignment, trauma, and instability caused by tumor or infection. Traditional iliac fixation with iliac screws or S2 alar/iliac (S2AI) screws may provide inadequate fixation in select clinical scenarios, such as severely compromised bone quality or spino...

2015
Thomas Henriques Bryan W. Cunningham Paul C. Mcafee Claes Olerud

PURPOSE Anterior plate fixation has been reported to provide satisfactory results in cervical spine distractive flexion (DF) injuries stages 1 and 2, but will result in a substantial failure rate in more unstable stage 3 and above. The aim of this investigation was to determine the biomechanical properties of different fixation techniques in a DF-3 injury model where all structures responsible ...

2010

INTRODUCTION: Structural cages have been widely used in recent years to maintain motion segment height and stability in anterior lumbar interbody fusion (ALIF). High rate of clinical success and radiological fusion rate have been reported following single-level fusion using these cages. However, many biomechanical studies report insufficient stability, especially with extension loading. Posteri...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید