نتایج جستجو برای: spo2

تعداد نتایج: 2000  

Journal: :Acta paediatrica 2013
J A Dawson A Saraswat L Simionato M Thio C O F Kamlin L S Owen G M Schmölzer P G Davis

AIM To compare heart rate (HR) measurements from Masimo and Nellcor pulse oximeters (POs) against HR measured via a three lead electrocardiograph (ECG) (HRECG ). We also compared peripheral oxygen saturation (SpO2 ) measurements between Nellcor and Masimo oximeters. METHOD Term infants born via elective caesarean section were studied. ECG leads were placed on the infant's chest and abdomen. M...

2015
Tomoki Kohyama Kiyoshi Moriyama Riichiro Kanai Mariko Kotani Kohji Uzawa Toru Satoh Tomoko Yorozu

PURPOSE Pulse oximetry is routinely used to continuously and non-invasively monitor arterial oxygen saturation (SaO2). When oxygen saturation by pulse oximeter (SpO2) overestimates SaO2, hypoxemia may be overlooked. We compared the SpO2 - SaO2 differences among three pulse oximeters in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who spent their daily lives in a poor oxyg...

2017
Siana Nkya Josephine Mgaya Florence Urio Abel Makubi Swee Lay Thein Stephan Menzel Sharon E. Cox Charles R. Newton Fenella J. Kirkham Bruno P. Mmbando Julie Makani

Fetal hemoglobin (HbF) and peripheral hemoglobin oxygen saturation (SpO2) both predict clinical severity in sickle cell disease (SCD), while reticulocytosis is associated with vasculopathy, but there are few data on mechanisms. HbF, SpO2 and routine clinical and laboratory measures were available in a Tanzanian cohort of 1175 SCD individuals aged≥5years and the association with SpO2 (as respons...

2017
Saro D. Farra Stephen S. Cheung Scott G. Thomas Ira Jacobs

The purpose of this study was to clarify if Ratings of Perceived Exertion (RPE) and self-selected exercise intensity are sensitive not only to alterations in the absolute level of arterial saturation (SPO2) but also the rate of change in SPO2. Twelve healthy participants (31.6 ± 3.9 y, 175.5 ± 7.7 cm, 73.3 ± 10.3 kg, 51 ± 7 mL·kg-1·min-1 [Formula: see text]) exercised four times on a cycle ergo...

2017
Thomas Marian Jens Schröder Paul Muhle Inga Claus Stephan Oelenberg Christina Hamacher Tobias Warnecke Sonja Suntrup-Krüger Rainer Dziewas

BACKGROUND Dysphagia is one of the most dangerous symptoms of acute stroke. Various screening tools have been suggested for the early detection of this condition. In spite of conflicting results, measurement of oxygen saturation (SpO2) during clinical swallowing assessment is still recommended by different national guidelines as a screening tool with a decline in SpO2 ≥2% usually being regarded...

Journal: :Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies 2017
Samiran Ray Libby Rogers Christina Pagel Sainath Raman Mark J Peters Padmanabhan Ramnarayan

OBJECTIVES To derive a relationship between the SpO2/FIO2 ratio and PaO2/FIO2 ratio across the entire range of SpO2 values (0-100%) and to evaluate whether mortality prediction using the Pediatric Index of Mortality-3 can be improved by the use of PaO2/FIO2 values derived from SpO2/FIO2. DESIGN Retrospective analysis of prospectively collected data. SETTING A regional PICU transport service...

Journal: :The Journal of pediatrics 2014
Kathleen Lim Kevin I Wheeler Timothy J Gale Hamish D Jackson Jonna F Kihlstrand Cajsa Sand Jennifer A Dawson Peter A Dargaville

OBJECTIVE The precision of oxygen saturation (SpO2) targeting in preterm infants on continuous positive airway pressure (CPAP) is incompletely characterized. We therefore evaluated SpO2 targeting in infants solely receiving CPAP, aiming to describe their SpO2 profile, to document the frequency of prolonged hyperoxia and hypoxia episodes and of fraction of inspired oxygen (FiO2) adjustments, and...

2015
Gokcen Basaranoglu Mefkur Bakan Tarik Umutoglu Seniyye Ulgen Zengin Kadir Idin Ziya Salihoglu

Pulse oximetry is a frequently used tool in anesthesia practice. Gives valuable information about arterial oxygen content, tissue perfusion and heart beat rate. In this study we aimed to provide the comparison of peripheral capillary hemoglobin oxygen saturation (SpO2) values among every finger of the two hands. Thirty-seven healthy volunteers from operative room stuffs between the ages of 18-3...

2018
Mark van Gastel Hangbing Liang Sander Stuijk Gerard de Haan

Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample fro...

2016
Marcel Simon Christian Wachs Stephan Braune Geraldine de Heer Daniel Frings Stefan Kluge

BACKGROUND: Critically ill patients with respiratory failure undergoing intubation have an increased risk of hypoxemia-related complications. Delivering oxygen via a high-flow nasal cannula (HFNC) has theoretical advantages and is increasingly used. This study was conducted to compare HFNC with bag-valve-mask (BVM) for preoxygenation and to assess oxygenation during intubation in subjects with ...