نتایج جستجو برای: stard

تعداد نتایج: 181  

Journal: :Investigative ophthalmology & visual science 2006
Manoharan Shunmugam Augusto Azuara-Blanco

PURPOSE Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS A validated Medline and hand search of English-language articles reporting on measu...

2017
Gianni Virgili Manuele Michelessi Alba Miele Francesco Oddone Giada Crescioli Valeria Fameli Ersilia Lucenteforte

AIM To investigate the reproducibility of the updated Standards for the Reporting of Diagnostic Accuracy Studies tool (STARD 2015) in a set of 106 studies included in a Cochrane diagnostic test accuracy (DTA) systematic review of imaging tests for diagnosing manifest glaucoma. METHODS One senior rater with DTA methodological and clinical expertise used STARD 2015 on all studies, and each of t...

Journal: :Clinical chemistry 2007
Sandrine Daval Arlette Tridon Nicole Mazeron Jean-Michel Ristori Bertrand Evrard

1. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, et al. Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative. Clin Chem 2003;49:1–6. 2. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, et al. The STARD statement for reporting studies of diagnostic accuracy: explanation and elaboration. Clin Chem 2003;49:7–18...

2011
Tara J Selman R Katie Morris Javier Zamora Khalid S Khan

BACKGROUND In obstetrics and gynaecology there has been a rapid growth in the development of new tests and primary studies of their accuracy. It is imperative that such studies are reported with transparency allowing the detection of any potential bias that may invalidate the results. The objective of this study was to determine the quality of reporting in diagnostic test accuracy studies in ob...

Journal: :Preventive veterinary medicine 2011
Ian A Gardner Søren S Nielsen Richard J Whittington Michael T Collins Douwe Bakker Beth Harris Srinand Sreevatsan Jason E Lombard Raymond Sweeney David R Smith Jerrie Gavalchin Shigetoshi Eda

The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy studies and the finding that incomplete or absent reporting of items in the STARD checklist was associat...

2009
Patricia Scolari Fontela Nitika Pant Pai Ian Schiller Nandini Dendukuri Andrew Ramsay Madhukar Pai

BACKGROUND Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic re...

Journal: :BMC Medical Research Methodology 2006
Nynke Smidt Anne WS Rutjes Daniëlle AWM van der Windt Raymond WJG Ostelo Patrick M Bossuyt Johannes B Reitsma Lex M Bouter Henrica CW de Vet

BACKGROUND In January 2003, STAndards for the Reporting of Diagnostic accuracy studies (STARD) were published in a number of journals, to improve the quality of reporting in diagnostic accuracy studies. We designed a study to investigate the inter-assessment reproducibility, and intra- and inter-observer reproducibility of the items in the STARD statement. METHODS Thirty-two diagnostic accura...

2017
Manuele Michelessi Ersilia Lucenteforte Alba Miele Francesco Oddone Giada Crescioli Valeria Fameli Daniël A Korevaar Gianni Virgili

BACKGROUND Research has shown a modest adherence of diagnostic test accuracy (DTA) studies in glaucoma to the Standards for Reporting of Diagnostic Accuracy Studies (STARD). We have applied the updated 30-item STARD 2015 checklist to a set of studies included in a Cochrane DTA systematic review of imaging tools for diagnosing manifest glaucoma. METHODS Three pairs of reviewers, including one ...

2016
Chun-Kuei Chen Shen-Che Lin Chin-Chieh Wu Li-Min Chen I-Shiang Tzeng Kuan-Fu Chen

Sepsis is a common condition in the emergency department that is associated with high mortality. Red blood cell distribution width (RDW) has been used as a simple prognosis predictor for patients with community-acquired pneumonia, gram-negative bacteremia, and severe sepsis or septic shock. To evaluate the performance of RDW to predict in-hospital mortality among septic patients, we conducted a...

2015
Claudio Chiesa Lucia Pacifico John F. Osborn Enea Bonci Nora Hofer Bernhard Resch Medows. Marsha

To perform a systematic review assessing accuracy and completeness of diagnostic studies of procalcitonin (PCT) for early-onset neonatal sepsis (EONS) using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative.EONS, diagnosed during the first 3 days of life, remains a common and serious problem. Increased PCT is a potentially useful diagnostic marker of EONS, but reports in the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید