نتایج جستجو برای: stress shielding
تعداد نتایج: 447020 فیلتر نتایج به سال:
Stress shielding is a well-known failure factor in hip implants. This work proposes a design concept for hip implants, using a combination of metallic stem with a polymer coating (polyether ether ketone (PEEK)). The proposed design concept is simulated using titanium alloy stems and PEEK coatings with thicknesses varying from 100 to 400 μm. The Finite Element analysis of the cancellous bone sur...
BACKGROUND Conventional total knee replacement designs show high success rates but in the long term, the stiff metal components may affect bone quality of the distal femur. In this study we introduce an all-polymer total knee replacement device containing a PEEK femoral component on an UHMWPE tibial implant and study its mechanical integrity, fixation, and stress shielding of the periprosthetic...
Research concerning the impact of psychological stress on visual selective attention has produced mixed results. The current paper describes two experiments which utilise a novel auditory oddball paradigm to test the impact of psychological stress on auditory selective attention. Participants had to report the location of emotionally-neutral auditory stimuli, while ignoring task-irrelevant chan...
The aim of this study is to investigate the behavior of the healthy mandible under maximum molar bite force to demonstrate the problems associated with the current standard of care procedures for mandibular segmental defect reconstruction (ie, use of Ti-6Al-4V hardware and either a single- or double-barrel fibular graft). With current Ti-6Al-4V mandibular reconstruction hardware, there is a sig...
BACKGROUND The influence of varus insertion of femoral implants in uncemented total hip replacement arthroplasty (THR) remains unclear. Thus, in this study, we retrospectively assessed the clinical impact of uncemented THR with femoral implants that were inserted in varus on the basis of radiological findings. MATERIALS AND METHODS The study participants included 89 patients who underwent unc...
Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with ...
The health of physiological tissue is governed by the continuous conversion of mechanical stimulus (stress) to bio-chemical response, a concept known as mechanical homeostasis. If this regulatory imperative becomes flawed, it may be detrimental, and consequently invoke or encourage the progression of various musculoskeletal disorders. This notion is corroborated by the quantification of altered...
K. T. Faber Department of Materials Science and Engineering, Northwestern University Evanston, IL 60208 There is experimental evidence that stress-induced microcracking near a macrocrack tip enhances thefraclUre toughness of brittle materials. In considering the interaction of the macrocrack with multiple microcracks using a discrete model, it is essential to use approximation methods in order ...
The intent of shielding functions in delayed detached-eddy simulation methods (DDES) is to preserve the wall boundary layers as Reynolds-averaged Navier–Strokes (RANS) mode, avoiding possible modeled stress depletion (MSD) or even unphysical separation due to grid refinement. An entropy function f s is introduced to construct a DDES formulation for the k-ω shear stress transport (SST) model, wh...
Today, different implant designs exist in the market; however, there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. Therefore, the aim of this project was to investigate if the geometry of a commercial short stem hip prosthesis can be further optimized to reduce stress shielding effects and achieve better short-stemmed impl...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید