نتایج جستجو برای: strut

تعداد نتایج: 2011  

2017
Koun Yamauchi Kazunari Fushimi Kei Miyamoto Akira Hioki Katsuji Shimizu Haruhiko Akiyama

Study Design Retrospective study. Purpose The purpose of this study was to investigate the influence of sagittal alignment of the strut graft on graft subsidence and clinical outcomes after anterior cervical corpectomy and fusion (ACCF). Overview of Literature ACCF is a common technique for the treatment of various cervical pathologies. Although graft subsidence sometimes occurs after ACCF,...

Journal: :international journal of civil engineering 0
a. arabzadeh a.r. rahaie a. aghayari

in this paper a new method based on strut-and-tie model (stm) is proposed to determine the shear capacity of simply supported rc deep beams and an efficiency factor for concrete with considering the effect of web reinforcements. it is assumed that, the total carried shear force by rc deep beam provided by two independent resistance, namely diagonal concrete strut due to strut-and-tie mechanism ...

Journal: :Circulation 2005
Brinda Balakrishnan Abraham R Tzafriri Philip Seifert Adam Groothuis Campbell Rogers Elazer R Edelman

BACKGROUND The intricacies of stent design, local pharmacology, tissue biology, and rheology preclude an intuitive understanding of drug distribution and deposition from drug-eluting stents (DES). METHODS AND RESULTS A coupled computational fluid dynamics and mass transfer model was applied to predict drug deposition for single and overlapping DES. Drug deposition appeared not only beneath re...

2016
Yuan Zhang Xu Deng Dianming Jiang Xiaoji Luo Ke Tang Zenghui Zhao Weiyang Zhong Tao Lei Zhengxue Quan

To assess the long-term clinical and radiographic outcomes of anterior cervical corpectomy and fusion (ACCF) with a neotype nano-hydroxyapatite/polyamide 66 (n-HA/PA66) strut in the treatment of cervical spondylotic myelopathy (CSM). Fifty patients with CSM who underwent 1- or 2-level ACCF with n-HA/PA66 struts were retrospectively investigated. With a mean follow-up of 79.6 months, the overall...

2009
J. E. Wright

More maths than engineering. Show how simple the model is. Mention the isotropic strut by reference. Focus on the bimaterial strut. Analysis and placement of the bifurcation. Normal form for the bifurcation? Root structure?

Journal: :Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia 2001
S Watarida S Shiraishi T Nishi M Imura Y Yamamoto R Hirokawa M Fujita

BACKGROUND The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. METHODS AND RESULTS T...

Journal: :Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 2018
Rishi Puri Imanol Otaegui Manel Sabaté Antonio Serra-Peñaranda Marti Puigfel Armando Perez de Prado Luis Nombela-Franco Jose M de la Torre Hernandez Rosario Ortas Nadal Andres Iniguez-Romo Gustavo Jiménez Felipe Fernandez-Vazquez Carlos Cuellas-Ramon Nieves Gonzalo Victor Alfonso Jiménez Diaz Lluis Duocastella Maria Molina Marc Amoros Isabel Perez Alberto Barria Perez Emilie Pelletier Beaumont Stephen J Nicholls Bruno Garcia Del Blanco Josep Rodés-Cabau

BACKGROUND Pre-clinical results of a novel open-cell, thin strut, durable polymer, laser cut cobalt chromium sirolimus-eluting stent (Angiolite) were promising. Using quantitative optical coherence tomographic (OCT) analyses, we explored the healing characteristics of the Angiolite DES system at 3- and 6-months post implantation. METHODS A total of 103 patients with de novo coronary lesions u...

Journal: :Revista espanola de cardiologia 2010
Pawel Tyczynski Giuseppe Ferrante Cristina Moreno-Ambroj Neville Kukreja Peter Barlis Elio Pieri Ranil De Silva Kevin Beatt Carlo Di Mario

INTRODUCTION AND OBJECTIVES Stenting of coronary bifurcation lesions carries an increased risk of stent deformation and malapposition. Anatomical and pathological observations indicate that the high stent thrombosis rate in bifurcations is due to malapposition of stent struts. METHODS Strut apposition was assessed with optical coherence tomography (OCT) in bifurcation lesions treated either u...

Journal: :European cells & materials 2013
M Mehta M Heyland D Toben G N Duda

Non-invasive assessment of fracture healing, both in clinical and animal studies, has gained favour as surrogate measure to estimate regain of mechanical function. Micro-computed tomography (µCT) parameters such as fracture callus volume and mineralisation have been used to estimate callus mechanical competence. However, no in-depth information has been reported on microstructural parameters in...

2008
Yong Hyun Kim Sam Farhat Xiafeng Xu Joon Sang Lee

The analysis of a flow pattern in cerebral aneurysms and the effect of strut shapes and stent porosity in 2D and 3D model are presented in this paper. The efficiency of a stent is related to several parameters, including porosity and stent strut shapes. The goal of this paper is to identify numerically how the stent strut shape and the porosity affect the hemodynamics properties of the flow ins...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید