نتایج جستجو برای: thermoluminescence dosimeters tld
تعداد نتایج: 3413 فیلتر نتایج به سال:
The phosphate glass samples doped with Tb2O3 oxide (general formula: P2O5-Al2O3-Na2O-Tb2O3) were synthesized and studied for usage in high-dose radiation dosimetry (for example, high-activity nuclear waste disposals). influence of terbium concentration on thermoluminescent (TL) signals was analyzed. TL properties glasses investigated using various experimental techniques such as direct measurem...
BACKGROUND The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective : In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. METHO...
background: the number of interventional cardiology procedures performed has increased rapidly over the past years. while these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. the dose received by the cardiologist during interventional cardiology procedures is determi...
background: thermoluminescence dosimetry is one of the dosimetry procedures used widely as routine and personal dosimeters. in order to extend this kind of dosimeters, dental tissue has been examined and was found promising as a tld dosimeter. materials and methods : in this study, 70 health teeth were collected. the only criterion, which was considered for selection of the teeth, was the healt...
background: 7-lif: mg,cu,p (gr-207a) is one kind of thermo-luminescent dosimeters (tld) which can be used in diagnostic radiology and radiotherapy applications. because of having suitable properties such as good sensitivity, small size and being tissue equivalent, thermo-luminescent dosimetry has been one of the most important techniques in medicine over many years. choosing a correct energy fo...
Noting an increase in demand for procedures involving clinical radiosurgery we seek to develop a high spatial resolution thermoluminescence dosimeter (TLD) allow conduct of vivo dose verification measurements. An associated need is dynamic range exceeding that the well-established LiF (Mg,Ti) phosphor TLD-100, with particular latter being limited performance at elevated doses seen radiotherapy....
The purpose of this comparative study was to test the accuracy of anisotropic analytical algorithm (AAA) and pencil beam convolution (PBC) algorithms of Eclipse treatment planning system (TPS) for dose calculations in the low- and high-dose buildup regions. AAA and PBC algorithms were used to create two intensity-modulated radiotherapy (IMRT) plans of the same optimal fluence generated from a c...
Background: Thermoluminescence dosimetry is one of the dosimetry procedures used widely as routine and personal dosimeters. In order to extend this kind of dosimeters, dental tissue has been examined and was found promising as a TLD dosimeter. Materials and Methods : In this study, 70 health teeth were collected. The only criterion, which was considered for selection of the teeth, was the healt...
Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید