نتایج جستجو برای: titanium zirconium

تعداد نتایج: 42255  

Journal: :Nano letters 2011
Peilin Liao Maytal Caspary Toroker Emily A Carter

Hematite (α-Fe(2)O(3)) is a promising candidate for photoelectrochemical splitting of water. However, its intrinsically poor conductivity is a major drawback. Doping hematite to make it either p-type or n-type enhances its measured conductivity. We use quantum mechanics to understand how titanium, zirconium, silicon, or germanium n-type doping affects the electron transport mechanism in hematit...

2013
Yolanda Hedberg Jonas Hedberg Inger Odnevall Wallinder

Titanium oxide (rutile, TiO2) and zircon (ZrSiO4), known insoluble ceramic materials, are commonly used for coatings of implant materials. We investigate the release of zirconium, titanium, aluminum, iron, and silicon from different micron-sized powders of 6 powders of natural rutile (TiO2) and zircon (ZrSiO4) from a surface perspective. The investigation includes five different synthetic body ...

Journal: :Dental materials : official publication of the Academy of Dental Materials 2014
Bingran Zhao Henny C van der Mei Guruprakash Subbiahdoss Joop de Vries Minie Rustema-Abbing Roel Kuijer Henk J Busscher Yijin Ren

OBJECTIVE Dental implants anchor in bone through a tight fit and osseo-integratable properties of the implant surfaces, while a protective soft tissue seal around the implants neck is needed to prevent bacterial destruction of the bone-implant interface. This tissue seal needs to form in the unsterile, oral environment. We aim to identify surface properties of dental implant materials (titanium...

Precipitation behaviour of wrought Al-6Mg alloys with ternary scandium and quaternary zirconium and titanium has been studied. Hardness measurements and resistivity studies are employed to assess the precipitation behaviour of scandium doped Al-6Mg alloy without or with quaternary additions of zirconium and titanium. Further, the kinetics of precipitations are studied by differential scanning c...

Journal: :The International journal of oral & maxillofacial implants 2017
Francisco Martínez-Rus Marta Prieto María P Salido Cristina Madrigal Mutlu Özcan Guillermo Pradíes

PURPOSE To assess the influence of anodized titanium and zirconium dioxide abutments and peri-implant soft tissue thickness on the optical outcome of implant-supported lithium disilicate single crowns. MATERIALS AND METHODS Twenty patients with a missing maxillary single incisor, canine, or first premolar received an endosseous implant after a two-stage surgery protocol. After healing and sof...

Journal: :Chemical reviews 2003
Harald Gröger

3.1. Overview 2807 3.2. Chiral Aluminum(III) Complexes as a Catalyst 2808 3.2.1. Aluminum(III)-Salen-Based Catalysts 2808 3.2.2. Aluminum(III)-Binaphthol-Based Catalysts 2810 3.3. Chiral Titanium(IV) Complexes as a Catalyst 2814 3.3.1. Titanium(IV)-Peptide-Based Catalysts 2814 3.3.2. Titanium(IV)-Diol-Based Catalysts 2817 3.4. Chiral Zirconium(IV) Complexes as a Catalyst 2818 3.4.1. The Catalyt...

Journal: :Dalton transactions 2014
Srinivas Anga Kishor Naktode Harinath Adimulam Tarun K Panda

We report here a number of dianionic 1,4-diaza-1,3-butadiene complexes of titanium and zirconium synthesised by a salt metathesis reaction. The reaction of either CpTiCl3 or Cp2TiCl2 with the dilithium salt of N,N'-bis(2,6-diisopropylphenyl)-1,4-diaza-1,3-butadiene [; abbreviated (Dipp)2DADLi2] afforded the mono-cyclopentadienyl titanium complex [η(5)-CpTi((Dipp)2DAD)Cl] () bearing a dianionic ...

2011
D. R Prithviraj

Dental implants constitute a well-established approach for replacement of lost teeth with titanium being the most favored material for implantation. However, titanium has its limitations in esthetically demanding cases and neither the form nor material of such implants has changed much over the past 40 years. Immediate implantation has been introduced to overcome the disadvantages of convention...

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

2012
Michael Plecko Christine Sievert Daniel Andermatt Robert Frigg Peter Kronen Karina Klein Stefan Stübinger Katja Nuss Alexander Bürki Stephen Ferguson Ulrich Stoeckle Brigitte von Rechenberg

BACKGROUND In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. METHODS Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید