نتایج جستجو برای: tof pet

تعداد نتایج: 65497  

2013
Mattijs Elschot Bart J. Vermolen Marnix G. E. H. Lam Bart de Keizer Maurice A. A. J. van den Bosch Hugo W. A. M. de Jong

BACKGROUND After yttrium-90 ((90)Y) microsphere radioembolization (RE), evaluation of extrahepatic activity and liver dosimetry is typically performed on (90)Y Bremsstrahlung SPECT images. Since these images demonstrate a low quantitative accuracy, (90)Y PET has been suggested as an alternative. The aim of this study is to quantitatively compare SPECT and state-of-the-art PET on the ability to ...

2012
Wu Gao Deyuan Gao Christine Hu-Guo Yann Hu

PET with time-of-flight (TOF) capability has been shown to provide a better reconstructed image compared to conventional positron tomography. The increase in SNR mainly depends on the size of the patient being imaged Conti (2009), the intrinsic resolution of the detector and the resolution of the TOF. In TOF-PET approach, for each detected event, the measurement of the time of flight difference...

Journal: :Physics in medicine and biology 2008
Sanghee Cho Sangtae Ahn Quanzheng Li Richard M Leahy

We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the 'bow-tie' property of the 2D Radon transform to the time-of-flight case. Second, we describe a new exact Fouri...

Journal: :American journal of nuclear medicine and molecular imaging 2015
Jorge D Oldan Timothy G Turkington Kingshuk Choudhury Bennett B Chin

[(18)F] sodium fluoride (NaF) PET/CT is a current, clinically relevant method to assess bone metastases. Time-of-flight (TOF) PET provides better statistical data quality, which can improve either lower image noise or improve resolution, or both, depending on the image reconstruction. Improved resolution can improve quantitative measurements of standardized uptake value (SUV) in small structure...

Journal: :Physics in medicine and biology 2017
S E Brunner D R Schaart

Due to detector developments in the last decade, the time-of-flight (TOF) method is now commonly used to improve the quality of positron emission tomography (PET) images. Clinical TOF-PET systems based on L(Y)SO:Ce crystals and silicon photomultipliers (SiPMs) with coincidence resolving times (CRT) between 325 ps and 400 ps FWHM have recently been developed. Before the introduction of L(Y)SO:Ce...

Journal: :IEEE transactions on radiation and plasma medical sciences 2022

Depth-of-interaction (DOI) positron emission tomography (PET) detector with time-of-flight (TOF) readout has been developed in recent years. With DOI, PET scanner could achieve high spatial resolution and sensitivity simultaneously. improved TOF readout, better coincidence time (CTR) is achieved, making the localization of events along lines response (LORs) more accurate enhancing reconstructed...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2011
Georges El Fakhri Suleman Surti Cathryn M Trott Joshua Scheuermann Joel S Karp

UNLABELLED Time-of-flight (TOF) PET has great potential in whole-body oncologic applications, and recent work has demonstrated qualitatively in patient studies the improvement that can be achieved in lesion visibility. The aim of this work was to objectively quantify the improvement in lesion detectability that can be achieved in lung and liver lesions with whole-body (18)F-FDG TOF PET in a coh...

2017
Tanja Kero Jonny Nordström Hendrik J. Harms Jens Sörensen Håkan Ahlström Mark Lubberink

BACKGROUND The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mea...

Journal: :Physics in medicine and biology 2005
Maurizio Conti Bernard Bendriem Mike Casey Mu Chen Frank Kehren Christian Michel Vladimir Panin

Time-of-flight (TOF) positron emission tomography (PET) was studied and preliminarily developed in the 1980s, but the lack of a scintillator able to deliver at the same time proper time resolution and stopping power has prevented this technique from becoming widespread and commercially available. With the introduction of LSO in PET, TOF is now a feasible option. TOF reconstruction has been impl...

Journal: :Revista espanola de medicina nuclear e imagen molecular 2013
J M Martí-Climent E Prieto I Domínguez-Prado M J García-Velloso M Rodríguez-Fraile J Arbizu C Vigil C Caicedo I Peñuelas J A Richter

OBJECTIVE To characterize the performance of the Biograph mCT PET/CT TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. MATERIAL AND METHODS The PET/CT scanner combines a 64-slice CT and PET scanner that incorporates in the reconstruction the TOF and PSF information. PET operating characteristics were evaluated according to the standard NEMA NU 2-2007, expanding...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید