نتایج جستجو برای: toric artisan

تعداد نتایج: 4582  

2013
Joo Youn Shin Jae Bum Lee Kyoung Yul Seo Eung Kweon Kim Tae-im Kim

PURPOSE To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometr...

Journal: :Journal of cataract and refractive surgery 2004
Ivanka J van der Meulen Frans P Gunning Muriel G Vermeulen Marc D de Smet

PURPOSE To report the results of pars plana vitrectomy (PPV) for retained lens fragments with implantation of an Artisan intraocular lens (IOL) (Ophtec) to correct aphakia. SETTING University-based referral center. METHODS In this retrospective case-controlled study, patients who had had a PPV to remove dislocated lens fragments and implantation of an Artisan IOL for pseudophakic correction...

Journal: :بینا 0
سیدجواد هاشمیان sj hashemian iran university of medical sciences, tehran, iranمرکز تحقیقات چشم - ﺩﺍﻧﺸﮕﺎﻩ ﻋﻠﻮﻡ ﭘﺰﺷﮑﻲ ایران- تهران- ایران فریبا بیگ زاده f beigzadeh iran university of medical sciences, tehran, iranمرکز تحقیقات چشم - ﺩﺍﻧﺸﮕﺎﻩ ﻋﻠﻮﻡ ﭘﺰﺷﮑﻲ ایران- تهران- ایران محمدابراهیم جعفری me jafari iran university of medical sciences, tehran, iranمرکز تحقیقات چشم - ﺩﺍﻧﺸﮕﺎﻩ ﻋﻠﻮﻡ ﭘﺰﺷﮑﻲ ایران- تهران- ایران

purpose: to evaluate the efficacy, safety, predictability and stability of implantable collamer lens (icl) and toric icl for the treat­ment of high myopia and high myopic astigmatism, one year prospective study. methods: in this prospective nonrandomized clinical trial, 95 eyes of 51 patients that had icl (31 eyes) and toric icl (64 eyes) were participate in eye research center, department of o...

Journal: :Journal of cataract and refractive surgery 2004
José L Menezo Cristina Peris-Martínez Angel L Cisneros Rafael Martínez-Costa

PURPOSE To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. SETTING La Fe University Hospital, Department of Ophthalmology, and the Fundación Oftalmológica del Mediterráneo, Valencia, Spain. METHODS In this prospective comparative study, a phakic IOL was implanted in 217 highly myopi...

1999
V. Broz O. Carmichael S. Thayer M. Hebert J. Osborn

Integration of three-dimensional textured scene mapping and object recognition presents many opportunities for assisted automation. We present Artisan, a software package that synthesizes these elements to form a user-friendly whole. Artisan uses a variety of 3D sensors, including laser range scanners and stereo systems, to acquire both image and range data. Artisan automatically finds the tran...

Journal: :بینا 0
فرید کریمیان f karimian ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی علیرضا برادران رفیعی a baradaran rafii ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی جواد هاشمیان j hashemian tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران علی هاشملو a hashemloo ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی ابراهیم جعفری e jafari tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران مهدی یاسری m yaseri ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranگروه بهداشت و آمار حیاتی- دانشگاه علوم پزشکی تهران

purpose: to compare visual outcomes and surgical complications of three phakic intraocular lenses (piols); artisan, artiflex and the implantable collamer lens (icl) for correction of moderate to high myopia. methods: in this historical cohort study, 112 myopic eyes that were operated between 2005 and 2010 and implanted with one of these three piols were evaluated (artisan 40 eyes, artiflex 36 e...

2014
Ahmad Kheirkhah Mojgan Nikdel Hadi Ghadimi

Implantation of iris-claw Artisan intraocular lens (IOL) is a surgical option for correction of aphakia; however, these IOLs have not been used in eyes with uveitis including Fuchs' heterochromic iridocyclitis (FHI) due to possible risk of severe postoperative intraocular inflammation. In the case reported here, we secondarily implanted an Artisan IOL in a 28-year-old man with FHI who had aphak...

Journal: :Journal of cataract and refractive surgery 2006
Günhal Kamburoğlu Mehmet Bahadir Aylin Ertan

We report a 50-year-old patient who had secondary implantation of an aphakic Artisan (Ophtec) intraocular lens (IOL) that was placed vertically in the anterior chamber. The patient had had a perforating injury to the cornea that required corneal wound repair, lensectomy, and anterior vitrectomy. Because of the localized traumatic aniridia, the Artisan IOL could not be placed horizontally. Three...

2006
Marije L. Sminia Liesbeth J. J. M. Prick Nitza Gortzak-Moorstein

Purpose: To retrospectively estimate the long-term corneal endothelial cell loss in children after perforating corneal trauma and implantation of an iris-fixated anterior-chamber intraocular lens (IOL), either the Artisan aphakia lens or the Artificial Iris Implant, and to compare this corneal endothelial cell loss to that in children who received an Artisan aphakia lens to correct aphakia afte...

2010
Juan Carlos Castilla

Fishery-management policies based on the allocation of exclusive fishing rights, territorial use rights, and sea zoning are recurrent tools for achieving sustainability. In Chile, the 1991 Fishery and Aquaculture Law reformed division of the right to fish between the artisan and industrial subsectors, introduced sea-zoning (spacebased) strategies, and established a differential individual trans...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید