نتایج جستجو برای: volumetric modulated arc radiotherapy

تعداد نتایج: 173599  

Journal: :Head & neck 2004
Robert J Amdur Jonathan G Li Chihray Liu Russell W Hinerman William M Mendenhall

PURPOSE The purpose of this review is to address the issue of unnecessary irradiation of the normal larynx. METHODS We performed a literature review and dosimetry evaluation of intensity modulated radiotheraphy (IMRT) techniques. RESULTS Data suggest that matching conventional parallel opposed photon fields through adenopathy is a reasonable alternative to the common practice of unnecessari...

Journal: :Journal of cancer research and therapeutics 2008
Rajesh A Kinhikar

The purpose of this study was to measure the multileaf collimator (MLC) transmission from the first Hi-Art II tomotherapy machine installed at the Advanced Center for Treatment, Research, and Education in Cancer (ACTREC). The MLC transmission was measured with an A1SL ion chamber and the radiographic extended dose range (EDR2) film in virtual water slabs at 1.5-cm depth with a source-to-surface...

2010
Jean M. Moran

As the complexity of radiation therapy has increased, the need for quantitative dosimetric evaluation of treatment delivery has also increased. A growing number of investigations have expanded the use of EPIDs from anatomic applications to dosimetric verification. This work focuses on the applications of EPIDs for pre-treatment dosimetric verification of IMRT and intensity modulated arc therapy...

2003
Nzhde Agazaryan Timothy D. Solberg John J. DeMarco

A patient specific quality assurance program has been developed to facilitate the clinical implementation of intensity modulated radiotherapy (IMRT) delivered using a micro-multileaf collimator. The methodology includes several dosimetric tasks that are performed prior to the treatment of each patient. Film dosimetry is performed for each individual field and for the multifield composite plan. ...

2016
Young Suk Kim Jaegi Lee Jong In Park Wonmo Sung Sol Min Lee Gwi Eon Kim

PURPOSE Radiotherapy of the neck is known to cause carotid artery stenosis. We compared the carotid artery dose received between volumetric modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (IMRT) plans in patients with early glottic cancer. MATERIALS AND METHODS Twenty-one early glottic cancer patients who previously underwent definitive radiotherapy ...

2010
Barbara Dobler Karin Weidner Oliver Koelbl

BACKGROUND AND PURPOSE The purpose of this study was to assess plan quality and treatment time achievable with the new VMAT optimization tool implemented in the treatment planning system Oncentra MasterPlan® as compared to IMRT for Elekta SynergyS® linear accelerators. MATERIALS AND METHODS VMAT was implemented on a SynergyS® linear accelerator (Elekta Ltd., Crawley, UK) with Mosaiq® record a...

2016
Jan Hofmaier Steffi Kantz Matthias Söhn Oliver S Dohm Stefan Bächle Markus Alber Katia Parodi Claus Belka Maximilian Niyazi

BACKGROUND The purpose of this study is to investigate the potential to reduce exposure of the contralateral hippocampus in radiotherapy for glioblastoma using volumetric modulated arc therapy (VMAT). METHODS Datasets of 27 patients who had received 3D conformal radiotherapy (3D-CRT) for glioblastoma with a prescribed dose of 60Gy in fractions of 2Gy were included in this planning study. VMAT...

Journal: :Cancer 2016
Steven H Lin Ning Zhang Joy Godby Jingya Wang Gary D Marsh Zhongxing Liao Ritsuko Komaki Linus Ho Wayne L Hofstetter Stephen G Swisher Reza J Mehran Thomas A Buchholz Linda S Elting Sharon H Giordano

BACKGROUND It is currently unclear whether the superior normal organ-sparing effect of intensity-modulated radiotherapy (IMRT) compared with 3-dimensional radiotherapy (3D) has a clinical impact on survival and cardiopulmonary mortality in patients with esophageal cancer (EC). METHODS The authors identified 2553 patients aged > 65 years from the Surveillance, Epidemiology, and End Results (SE...

2015
Vikren Sarkar Long Huang Prema Rassiah‐Szegedi Hui Zhao Jessica Huang Martin Szegedi Bill J. Salter

While modulated arc (mARC) capabilities have been available on Siemens linear accelerators for almost two years now, there was, until recently, only one treatment planning system capable of planning these treatments. The Eclipse treatment planning system now offers a module that can plan for mARC treatments. The purpose of this work was to test the module to determine whether it is capable of c...

Journal: :Asian Pacific journal of cancer prevention : APJCP 2015
Zhe-Ming Liu Xiao-Lin Ge Jia-Yan Chen Pei-Pei Wang Chi Zhang Xi Yang Hong-Cheng Zhu Jia Liu Qin Qin Li-Ping Xu Jing Lu Liang-Liang Zhan Hong-Yan Cheng Xin-Chen Sun

BACKGROUND Radiotherapy is an important treatment of choice for breast cancer patients after breast- conserving surgery, and we compare the feasibility of using dual arc volumetric modulated arc therapy (VMAT2), single arc volumetric modulated arc therapy (VMAT1) and Multi-beam Intensity Modulated Radiotherapy (M-IMRT) on patients after breast-conserving surgery. MATERIALS AND METHODS Thirty ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید