نتایج جستجو برای: water phantom

تعداد نتایج: 566361  

ژورنال: سنجش و ایمنی پرتو 2016

The determination of the dosimetry parameters of brachytherapy in the treatment of cancerous tumors as per the TG-43U1 protocol provided by the American Association of Physicists in Medicine should be done in the surrounding water source before clinical application. To achieve a good treatment result, various factors such as body tissues with different densities can have a decisive role so that...

2013
J.T.P. Cruz A. L. Rodriguez J. D. Trono

In this paper, amplification in dose due to the presence of gold nanoparticles was quantified using Monte Carlo N-Particle (MCNP) simulation. Simulation models included the irradiation of a 30 cm × 30 cm × 15 cm pure-water—volume phantom with a beam of 1.17 MeV and 1.33 MeV Cobalt spectral emissions as source. Planar and concentric water panel detectors placed at a distance of intervals of 0.1 ...

2010
Dengsong Zhu Carlos Austerlitz Sidi Benhabib Helvecio Mota Ron R. Allison Diana Campos

Four 16 cm diameter spherical phantoms were modeled in this study: a homogenous water phantom, and three water phantoms with 1 cm thick shell each made of different materials (PMMA, Plastic WaterTM and polystyrene). The PENELOPE Monte Carlo code was utilized to simulate photon beams from the Leksell Gamma Knife (LGK) unit and to determine absorbed dose to water (Dw) from a single 18 mm beam del...

2010
J. F. Dechent L. Buljubasich L. M. Scheiber H. W. Spiess

Figure 1: Left: three dimensional scheme of the phantom used for MRI experiments. Center tube is filled with PHIP substance (orange), outer tube contains water (blue). Right: the FIDs originating from the whole phantom. The blue signal stems from thermally polarized water and thermally polarized PHIP substanc. The red signal is generated by thermally polarized water and hyperpolarized PHIP subs...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2013
Susanne Ziegler Harald Braun Philipp Ritt Carsten Hocke Torsten Kuwert Harald H Quick

UNLABELLED With the recent advent of integrated PET/MR hybrid systems, the need for simultaneous PET and MR phantom measurements arises. Phantom fluids that are used in stand-alone MR systems, especially in larger phantoms and at a high magnetic field strength, are not necessarily applicable in PET imaging and vice versa. In this study, different approaches to fluid selection were considered an...

Maryam Papie, R Faghihi S Sina

Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...

Journal: :Medical physics 2005
Asa Palm Thomas LoSasso

The energy dependence of radiographic film can introduce dosimetric errors when evaluating photon beams. The variation of the film response, which is attributed to the changing photon spectrum with depth and field size, has been the subject of numerous publications in recent years. However, these data show large unexplained differences in the magnitude of this variation among independent studie...

2013
Masao Tanooka Hiroshi Doi Hideharu Miura Hiroyuki Inoue Yasue Niwa Yasuhiro Takada Masayuki Fujiwara Toshiyuki Sakai Kiyoshi Sakamoto Norihiko Kamikonya Shozo Hirota

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

2013

This study is aimed at verifying the dosimetric performance of a treatment planning system (TPS) and to as well compare the accuracy of the measured absorbed dose of the solid water phantom against the inhouse phantom. In this study, a phantom for use in radiotherapy treatment planning of human trunk anatomical region has been designed with six hollows for inserting materials mimicking differen...

2004
José A. Bencomo Connel Chu Victor M. Tello Sang Hyun Cho Geoffrey S. Ibbott

An evaluation of two anthropomorphic breast phantoms, which have been designed for quality assurance and dose verification of radiotherapy treatment of breast cancer patients, is presented. These phantoms are identical in terms of their dimensions and shape, and composed of several layers of either Plastic Water or tissue-equivalent material. Both water- and tissue-equivalent phantoms include l...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید