نتایج جستجو برای: 192ir
تعداد نتایج: 176 فیلتر نتایج به سال:
From Jan 1, 1983 to April 30, 1989, 32 patients underwent 38 endobronchial treatments with 192Ir, bronchoscopically inserted for treatment of endobronchial obstructions secondary to bronchogenic carcinoma. Thirty-four of the 38 treatments were far enough apart to allow separate response analysis. Thirty of the 34 patients were symptomatically improved or stable; 22 of 24 patients who could be e...
Background: The Patterson-Parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. These tables were created using the dosimetric data for 226Ra that was determined in air and were utilized for dose calculations around implants with Ra-equivalent radionuclides such as 137Cs and 192Ir. Therefore, the differences of the tissue attenuation ...
Relative absorbed dose energy response correction, R, for various radiochromic films in water phantom is calculated by the use of the Monte Carlo-based EGSnrc code system for high energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb. The corrections are calculated along the transverse axis of the sources (1-15 cm). The radiochromic films investigated are EBT, EBT2 (lot 020609 and lot 03110...
PURPOSE In this work, gold nanoparticles (GNPs) were embedded in the MAGIC-f polymer gel irradiated with the 192Ir brachytherapy sources. MATERIAL AND METHODS At the first plexiglas phantom was made as the human pelvis. The GNPs were synthesized with 15 nm in diameter and 0.1 mM (0.0197 mg/ml) in concentration by using a chemical reduction method. Then, the MAGIC-f gel was synthesized. The fa...
The MammoSite radiation therapy system is a novel technique for treatment of patients with early-stage breast cancer. It was developed to overcome the longer schedules associated with external-beam radiation therapy. It consists of a small balloon (4 cm in diameter) connected to an inflation channel and a catheter for the passage of a high dose rate 192Ir brachytherapy source. The device is pla...
Early stage oral cancer can be cured with oral brachytherapy, but whole-body radiation exposure status has not been previously studied. Recently, the International Commission on Radiological Protection Committee (ICRP) recommended the use of ICRP phantoms to estimate radiation exposure from external and internal radiation sources. In this study, we used a Monte Carlo simulation with ICRP phanto...
Several groups are developing ultra-miniature x-ray machines for clinical use in radiation therapy. Current systems are for interstitial radiosurgery and for intravascular insertion for irradiation to prevent re-stenosis. Typical generating voltages are low, in the 20 to 40 kV range. It is well established that the biological effectiveness of such low-energy photons is large compared with highe...
Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید