نتایج جستجو برای: 3d treatment planning

تعداد نتایج: 1749727  

2016
Juan Ren Wei Yuan Ruihua Wang Qiuping Wang Yi Li Chaofan Xue Yanli Yan Xiaowei Ma Li Tan Zi Liu

OBJECTIVE The purpose of this study was to comprehensively compare the 3-dimensional (3D) magnetic resonance imaging (MRI)-guided and conventional 2-dimensional (2D) point A-based intracavitary brachytherapy (BT) planning for cervical cancer with regard to target dose coverage and dosages to adjacent organs-at risk (OARs). METHODS A total of 79 patients with cervical cancer were enrolled to r...

2009
Agnieszka Cholewka Marta Szlag Krzysztof Ślosarek Brygida Białas

PURPOSE In this study two different pre-planning methods (2D vs. 3D) were compared in respect to the implant quality as judged by volumetric and dose parameters of the treatment plans. The aim of this work was to evaluate the influence of the imaging modalities used for pre-planning purpose to the treatment plan quality. MATERIAL AND METHODS Twenty-four patients treated with HDR multicatheter...

H. Gharaati, H.R. Baghani, S.M. Hosseini Daghigh, S.M.R. Aghamiri, S.R. Mahdavi,

Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...

Journal: :Radiation Oncology (London, England) 2008
Hans Paul van der Laan Wil V Dolsma John H Maduro Erik W Korevaar Johannes A Langendijk

BACKGROUND The shift from conventional two-dimensional (2D) to three-dimensional (3D)-conformal target definition and dose-planning seems to have introduced volumetric as well as geometric changes. The purpose of this study was to compare coverage of computed tomography (CT)-based breast and boost planning target volumes (PTV), absolute volumes irradiated, and dose delivered to the organs at ri...

Journal: :iranian journal of medical physics 0
somayeh nourollahi m.sc.in medical physics, faculty of medicine, tehran university of medical sciences, tehran, iran mahmoud allahverdi associate professor, medical physics dept., faculty of medicine, tehran university of medical sciences, tehran, iran mahbod esfahani m.sc.in medical physics, radiotherapy dept., cancer institute, tehran university of medical sciences, tehran, iran mehdi aghili assistant professor, radiotherapy dept., cancer institute, tehran university of medical sciences, tehran, iran vahid changizi assistant professor, radiology technology dept., faculty of allied medical sciences, tehran university of medical sciences, tehran, iran

introduction: the complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (ptv) result in perturbations in dose distribution. this problem can result in overdosage or underdosage in the match region of the three treatment fields. the purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

2017
Michael G. Herman Moody D. Wharam

Stephenson and Wiley demonstrate that three-dimensional (3D) CT-based simulation is an improvement in the simulation process. The growing importance of CT in radiation oncology treatment planning has been discussed previously [1] and is further emphasized in this article. The advantages of geometric optimization in three dimensions for radiation therapy treatment planning also are described. Th...

Journal: :Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti 2017
A Furdová Ad Furdová A Thurzo M Šramka M Chorvát G Králik

Nowadays 3D printing allows us to create physical objects on the basis of digital data. Thanks to its rapid development the use enormously increased in medicine too. Its creations facilitate surgical planning processes, education and research in context of organ transplantation, individualization prostheses, breast forms, and others.Our article describes the wide range of applied 3D printing te...

2008
Felix Hamza-Lup Ivan Sopin Omar Zeidan

External beam radiation therapy (EBRT) is an effective and widely accepted form of treatment for many types of cancer that requires extensive planning. Unfortunately, current treatment planning systems have limited or no available visual aid that combines patient volumetric models extracted from patient specific CT data with the treatment device in an inclusive 3D interactive simulation. We are...

Journal: :Asian Pacific journal of cancer prevention : APJCP 2014
Renu Madan Sushmita Pathy Vellaiyan Subramani Seema Sharma Bidhu Kalyan Mohanti Subhash Chander Sanjay Thulkar Lalit Kumar Vatsla Dadhwal

BACKGROUND Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. MATERIALS AND METHODS Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiothera...

2013
Wei Wang Jian Bin Li Hong Guang Hu Tao Sun Min Xu Ting Yong Fan Qian Shao

This study was performed to explore and compare the dosimetric variance caused by respiratory movement in the breast during forward-planned IMRT after breast-conserving surgery. A total of 17 enrolled patients underwent the 3DCT simulation scans followed by 4DCT simulation scans during free breathing. The treatment planning constructed using the 3DCT images was copied and applied to the end exp...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید