نتایج جستجو برای: accelerated corrosion

تعداد نتایج: 92636  

2014
Naga Chaitanya

Reinforced concrete beams are normally designed as under reinforced to provide ductile behavior such as the tensile moment of resistance. In coastal environment reinforcement corrosion is an obvious cause of deterioration of concrete structure, which affects the durability and service of reinforced concrete structure. Structural stability is majorly influenced by strength of concrete. Flexural ...

2011
Y-Y. Wu P. Lambert

Cathodic protection (CP) has been successfully employed to protect steel-framed masonry buildings from corrosion related damage. When a CP system is installed to protect the structural members, other metallic items which are within the fabric of the structure but are not in direct electrical continuity may suffer from stray current interactions, resulting in accelerated corrosion of the discont...

2014
Jin Xia Wei-Liang Jin

This paper presents an experimental investigation on the crack width induced by the corrosion of reinforcing steel bars in concrete. Reinforcing steel bars with different diameters were corroded using an accelerated test in three types of concrete members, including 24 beams with corroded stirrup and 20 beams with corroded longitudinal reinforcing steel bars. The corrosion patterns and rusts ch...

2014
See Wee Chee Frances M. Ross David Duquette Robert Hull

Localized corrosion refers to the accelerated dissolution of metals and alloys due to the breakdown of their protective passive films at select sites [1]. Developing an understanding of localized corrosion phenomena has significant practical importance due to the deleterious effects of pit formation on the integrity of structural materials. However, localized corrosion is a challenging problem ...

Cracking of the concrete cover due to corrosion is defined as the serviceability limit state of reinforced concrete structures. This study evaluated the influence of a mineral admixture i.e. nano wollastonite on corrosion performance and serviceability of reinforced concrete structures by performing an accelerated corrosion test on ten reinforced concrete beams under a sustained load. To do so,...

For rehabilitation of damaged concrete structures, the durability of repair overlay is a very important issue. Self-compacting concretes (SCC) are known as a suitable repair overlay materials. In this study, the durability of different self-compacting lightweight aggregate concretes (LWSCC) and effect of lightweight aggregate type on them is investigated. 3 mix designs of LWSCC containing three...

2014
J. Chen A. Jiang

The behavior of corroded steel–concrete composite beams under hogging moment was studied by experimental investigation and theoretical analysis. A total of eight specimens, six of which had corroded shear studs, were tested. The corrosion rate of studs ranged from 0 to approximately 50%. The constant-current accelerated corrosion method was adopted to accelerate the corrosion process. The loadi...

2015
Junhua Dong

The atmospheres in many cities along the coastal lines in the world have been rapidly changed to coastal-industrial atmosphere. Hence, it is vital to investigate the corrosion behavior of steel exposed to this kind of environment. In this present study, Electrochemical Impedance Spectrography (EIS) and film thickness measurement were applied to monitor the corrosion behavior of weathering steel...

2015
Shuaixing Wang Daoxin Liu Nan Du Qing Zhao Shuyun Liu Jinhua Xiao

The relationship between dissolved oxygen (DO) and corrosion behavior of X80 steel in acidic soil simulated solution was studied by potentiodynamic polarization curves, electrochemical impedance spectroscopy (EIS), scanning Kelvin probe technique (SKP) and X-ray diffraction (XRD). Results showed that the presence of DO accelerated the cathodic process of corrosion for X80 steel in the acidic so...

2017
Caitlin O’Brien Amanda McBride Arash E. Zaghi Kelly A. Burke Alex Hill

Recent advancements in metal fibers have introduced a promising new type of stainless steel fiber with high stiffness, high failure strain, and a thickness < 100 μm (<0.00394 in.) that can be utilized in a steel fiber-reinforced polymer. However, stainless steel is known to be susceptible to pitting corrosion. The main goal of this study is to compare the impact of corrosion on the mechanical p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید