نتایج جستجو برای: arterial pulse

تعداد نتایج: 211883  

Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...

Journal: :Stroke 1981
M E Langham K F To'mey T J Preziosi

The intraocular pressure (IOP), the intraocular pulse to pressure (pulse/pressure) relationship, and the ophthalmic arterial pressure have been measured in 20 patients with either unilateral or bilateral hemodynamically significant lesions of the internal carotid arteries (ICA) as determined from arteriography. Studies were repeated in 5 of hte patients after surgical endarterectomy on the obst...

Journal: :Clinical science 1997
M D Driscoll M O Arnold G E Marchiori L A Harker M H Sherebrin

1. Non-invasive recording techniques of the arterial pressure pulse will distort the arterial wall and may alter pulse wave measurements. We hypothesized that intersubject variability of these measurements would be reduced if recording forces were normalized to reflect individualized arterial occlusion forces. 2. In 10 normal male subjects (age 24 +/- 1 years), brachial, radial and finger arter...

Journal: :Hypertension 1999
M J Domanski B R Davis M A Pfeffer M Kastantin G F Mitchell

Increased arterial stiffness results in increased characteristic impedance of the aorta and increased pulse wave velocity, which increases systolic and pulse pressures. An association between increased pulse pressure and adverse cardiovascular events has been found in normotensive and hypertensive patient populations. Increased pulse pressure has also been associated with thickening of the caro...

Journal: :Yonago acta medica 2017
Akihiro Yamamoto Naoto Burioka Aritoshi Eto Takashi Amisaki Eiji Shimizu

Pulse oximeters are used to noninvasively measure oxygen saturation in arterial blood (SaO2). Although arterial oxygen saturation measured by pulse oximeter (SpO2) is usually indicated in 1% increments, the value of SaO2 from arterial blood gas analysis is not an integer. We have developed a new pulse oximeter that can measure SpO2 to one digit after the decimal point. The values of SpO2 from t...

2016
Eisuke Amiya Masafumi Watanabe Shogo Watanabe Munenori Takata Issei Komuro

PURPOSE The aim of this study is to investigate the relationship between arterial pulse amplitude change under increased shear stress and the presence of ischemic heart disease (IHD). METHODS This study comprised 31 subjects, including 14 subjects with IHD. We investigated the change in brachial artery pulse amplitude during flow-mediated dilation (FMD) using ultrasonography. RESULTS The ar...

2011
M. Huotari K. Määttä J. Kostamovaara

Arterial pulse wave analysis in time and frequency domain was carried out to find out biophysical and functional properties of artery walls measured with a photoplethysmographic (PPG) device. Because peripheral arterial disease (PAD) is a fatal problem all over the world, an easy diagnosis method would be needed. It could probably be diagnosed by PPG which is a non-invasive optical technique fo...

Journal: :Hypertension 2004
Gary F Mitchell Helen Parise Emelia J Benjamin Martin G Larson Michelle J Keyes Joseph A Vita Ramachandran S Vasan Daniel Levy

With advancing age, arterial stiffness and wave reflections increase and elevate systolic and pulse pressures. An elevated central pulse pressure is generally ascribed to increased wave reflection and portends an unfavorable prognosis. Using arterial tonometry, we evaluated central (carotid-femoral) and peripheral (carotid-brachial) pulse wave velocity, amplitudes of forward and reflected press...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید