نتایج جستجو برای: cantilever beam

تعداد نتایج: 116446  

2016
Mahidur R. Sarker Azah Mohamed Ramizi Mohamed

Energy harvester is a self-generating energy source which is able to run small scale electronic devices. It largely reduces the dependency on external power source. This paper represents the utilization of micro cantilever beam to develop a vibration based electromechanical systems (MEMS) piezoelectric energy harvester system. The proposed micro cantilever part has been developed by finite elem...

2013
Thomas Jin - Chee Liu Yu - Shen Chen

This paper discusses some notes on the vibration design for the piezoelectric cooling fan. After reviewing the fundamental formulas of the cantilever Euler beam, it is not easy to find the optimal design of the piezoelectric fan. The experiments also show the complicated results of the vibration behavior and air flow. Keywords—Piezoelectric cooling fan, vibration, cantilever Euler beam, air flow.

Journal: :نشریه دانشکده فنی 0
مسعود خیام

the fundamental natural frequency of vibration of an inflatable cantilever beam is computed from the system of the three equeations given for vibratory motion of the beam. the effect of various parameters is discussed, and it is shown that, as internal pressure increases, fundamental natural frequency will increase , indicating the stiffening characteristics of internal pressure. a single exper...

2009
Hendrik Frentrup Matthew S. Allen

For more than two decades, the Atomic Force Microscope (AFM) has provided valuable insights in nanoscale phenomena, and it is now widely employed by scientists from various disciplines. AFMs use a cantilever beam with a sharp tip to scan the surface of a sample both to image it and to perform mechanical testing. The AFM measures the deflection of the probe beam so one must first find the spring...

Arman Mohammadi, Farzad AyatollahzadehShirazi Mohammad Reza Zakerzadeh, Pooyan Nayyeri,

Energy harvesting is a conventional method to collect the dissipated energy of a system. In this paper, we investigate the optimal location of a piezoelectric element to harvest maximum power concerning different excitation frequencies of a vibrating cantilever beam. The cantilever beam oscillates by a concentrated sinusoidal tip force, and a piezoelectric patch is integrated on the beam to gen...

2012
P. Sangeetha

Micromechanical cantilevers show great potential as highly sensitive biochemical sensors. Cantilever-based sensing involves the transduction of a biomolecular interaction to a measurable mechanical change in the cantilever resulting from induced surface stresses added mass. In surface stress sensing applications, one side of the cantilever beam is rendered sensitive to a specific target molecul...

2017

Micromechanical cantilevers show great potential as highly sensitive biochemical sensors. Cantilever-based sensing involves the transduction of a biomolecular interaction to a measurable mechanical change in the cantilever resulting from induced surface stresses added mass. In surface stress sensing applications, one side of the cantilever beam is rendered sensitive to a specific target molecul...

Journal: :The Review of scientific instruments 2013
Huan Wang J C Fenton O Chiatti P A Warburton

Nanoscale mechanical resonators are highly sensitive devices and, therefore, for application as highly sensitive mass balances, they are potentially superior to micromachined cantilevers. The absolute measurement of nanoscale displacements of such resonators remains a challenge, however, since the optical signal reflected from a cantilever whose dimensions are sub-wavelength is at best very wea...

The aim of this paper is to compare the static deflections and stress results of layered and functionally graded composite beams under static load. In the comparison study, the results obtained for a cantilever beam under point load. The Timoshenko beam and the Euler-Bernoulli beam theories are used in the beam model. The energy based Ritz method is used for the solution of the problem and alge...

2017

Micromechanical cantilevers show great potential as highly sensitive biochemical sensors. Cantilever-based sensing involves the transduction of a biomolecular interaction to a measurable mechanical change in the cantilever resulting from induced surface stresses added mass. In surface stress sensing applications, one side of the cantilever beam is rendered sensitive to a specific target molecul...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید