نتایج جستجو برای: collimator detector response

تعداد نتایج: 1033857  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2002
Sharlini Sankaran Eric C Frey Karen L Gilland Benjamin M W Tsui

UNLABELLED Attenuation, photon scatter, and distance-dependent collimator-detector response are major degrading factors in myocardial SPECT images. The current study investigated whether compensation for these factors improves perfusion defect detectability, and compared the results for human observers with a previous study using a mathematical observer. METHODS Four methods were investigated...

Journal: :Journal of Radioanalytical and Nuclear Chemistry 2022

A prototype gamma-ray scanning system was designed to perform post-irradiation examination measurements of nuclear fuel. The is composed a coaxial high-purity germanium (HPGe) detector, collimator, and mechanical positioning stages that translate the fuel sample across front collimator. This paper documents design process, modeling laboratory characterization performed validate system. done usi...

Asghar Hadadi, Farshid babapoor Mofrad Jalil Pirayesh Islamian, Mohammad Khoshakhlagh Sedigheh Jafari

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2003
Bryon Mueller Michael K O'Connor Ira Blevis Deborah J Rhodes Robin Smith Douglas A Collins Stephen W Phillips

UNLABELLED The purpose of this study was to evaluate a small semiconductor-based gamma camera that may have applications in scintimammography. METHODS A small cadmium zinc telluride (CZT) detector was evaluated. The detector had a field of view of 20 x 20 cm with detector elements of 2.5 x 2.5 mm in size. Both short-bore (35 mm) and long-bore (50 mm) collimators, matched to the geometry of th...

Journal: :EJNMMI Physics 2021

Abstract Purpose The quantitative accuracy of Nuclear Medicine images, acquired for both planar and SPECT studies, is influenced by the isotope-collimator combination as well image corrections incorporated in iterative reconstruction process. These factors can be investigated optimised using Monte Carlo simulations. This study aimed to evaluate quantification 123 I with low-energy high resoluti...

2016
Yujiao Qin Hualiang Zhong Ning Wen Karen Snyder Yimei Huang Indrin J. Chetty

The goal of this study was to investigate small field output factors (OFs) for flat-tening filter-free (FFF) beams on a dedicated stereotactic linear accelerator-based system. From this data, the collimator exchange effect was quantified, and detector-specific correction factors were generated. Output factors for 16 jaw-collimated small fields (from 0.5 to 2 cm) were measured using five differe...

Journal: :Mathematics and Computers in Simulation 2010
Nico Lanconelli

Nowadays, Monte Carlo techniques are very common for the development of Nuclear Medicine systems. Simulations can be very helpful for the optimization of SPECT and PET cameras, and for investigating the importance of several physical effects involved in image formation. In this paper, a simulation study for evaluating various aspects inuencing image formation in detectors for Nuclear Medicine i...

A. Takavar, Gh. Shamsipour, M. Eftekhari, M. Sohrabi,

Background: In myocardial perfusion SPECT imaging, images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. Filters greatly affect quality of nuclear medicine images Materials and Methods: A phantom simulating heart left ventricle was built. About 1mCi of 99mTc was injected into the phantom. Images were taken from this phantom. Some fi...

1999
P. F. Bloser

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...

Journal: :Physics in medicine and biology 2000
I Laurette G L Zeng A Welch P E Christian G T Gullberg

The qualitative and quantitative accuracy of SPECT images is degraded by physical factors of attenuation, Compton scatter and spatially varying collimator geometric response. This paper presents a 3D ray-tracing technique for modelling attenuation, scatter and geometric response for SPECT imaging in an inhomogeneous attenuating medium. The model is incorporated into a three-dimensional projecto...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید