نتایج جستجو برای: column foundation connection
تعداد نتایج: 260350 فیلتر نتایج به سال:
Objectives: To investigate and compare the ductility performance of precast column foundation connection using method proposed by Park ASCE 31-03. Methods: Strength are most important parameters to resist earthquake forces for overall safety a structure. Evaluating from experiments is cumbersome process. From experimentally obtained load-displacement envelope, was evaluated four specimens Paula...
The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection represents a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised steel straps were used...
moment-resisting frames have extensive usage in earthquake-prone areas and high ability in energy dissipation.after the earthquake in northridge 1994,kobe 1995 fixed connections of steel structures have shown poor performance and generally they were caught brittle fracture of beam flange weld to the column.in order to remedy to avoid similar situations in future earthquakes,researchers introduc...
The present study is concerned with the simultaneous optimization of the size of components and the arrangement of connections for performance-based seismic design of low-rise SPSWs. Design variables include the size of beams and columns, the thickness of the infill panels, the type of each beam-to-column connection and the type of each infill-to-boundary frame connection. The objective functio...
Abstract: Reduced Beam Section (RBS) and Drilled Beam Section (DBS) are seismic moment resistant frame connections, introduced after 1994 Northridge earthquake. RBS connection has been tested under cyclic loading and showed acceptable performance. In this paper, seismic behavior of Drilled Beam Section (DBS) connection is studied numerically using finite element method. A drilled beam section ...
The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید