نتایج جستجو برای: concrete shear walls

تعداد نتایج: 179951  

Adding steel braces to reinforced concrete frames is a common way for seismic rehabilitation of these structures. Due to ease of installation and the possibility of creating openings in the braced bays, this method of rehabilitation has been more preferred than using shear walls. In this paper, three experimental specimens including a reinforced concrete frame, a reinforced concrete frame with ...

2010
Marlon L. Bazan

Fiber-reinforced polymer (FRP) products are used as an alternative to traditional methods for strengthening and retrofitting concrete and masonry structures to resist blast loads. The development and experimental validation of a methodology for modeling the response of blast loaded concrete and masonry structural components retrofitted with FRP, as well as corresponding response criteria, is im...

Using of CFRP carbon sheets because of their high strength, lightness and ease of use have been very expanded in retrofitting concrete members. Including shear walls systems FRP can be used in order to rebuild or maintain the strength of an aged structural member. Repairing, or retrofitting of the intact structural member is conducted to enhance the structural resistance that was deteriorated d...

Journal: :Bulletin of the New Zealand Society for Earthquake Engineering 1982

Journal: :Bulletin of the New Zealand Society for Earthquake Engineering 1984

Self-centering rocking walls are known as viable alternatives to typical shear walls, as they provide a number of solutions for eliminating seismic flaws of conventional designs. These rocking walls have a generally positive impact on the seismic behavior of structural systems, but their design makes them susceptible to concrete crushing around their base, which can lead to significantly advers...

Journal: :Journal of Structural and Construction Engineering (Transactions of AIJ) 1993

Journal: :Journal of Structural and Construction Engineering (Transactions of AIJ) 1987

2013
Brian J. Smith Yahya C. Kurama

This paper presents an analytical investigation on the peak lateral displacement demands of “hybrid” precast concrete panelized shear wall structures under seismic loading. The hybrid wall structure investigated uses a combination of mild [i.e., Grade 400 (U.S. Grade 60)] steel bars and highstrength unbonded post-tensioning (PT) strands for lateral resistance across horizontal joints. The analy...

C. Freeda Christy D. Tensing, S. Vincent Sam Jebadurai

Masonry infill has been widely used as building material due to its cost effectiveness and availability.  The failure of these masonry infill walls during the past earthquakes have underscored the importance of ensuring the safety of the infill walls when it is subjected to lateral loads. In-plane and out of plane failures have been observed in many reinforced concrete framed building with maso...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید