نتایج جستجو برای: condenser waste heat
تعداد نتایج: 281563 فیلتر نتایج به سال:
A hybrid heat pump cycle of the heat amplifier type integrating a booster compressor between the generator and the condenser for distributed heating is simulated and analyzed. The interrelation between the two sub-cycles and the hybridization principle are explored. The theoretical analysis is demonstrated by a H2O/LiBr based hybrid cycle simulation. Investigation of the interaction mechanisms ...
A manufacturing process plan was developed for a welded condenser utilizing a sintered wick. Electronic devices have progressed to the point where new designs are limited by the thermal management system used to ensure safe operating temperatures. Coupling the effects of high surface area of multiple condensers, the low thermal resistance of loop heat pipes, and the increased dissipation rates ...
The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average te...
Flat tube heat exchangers with louvered fins were applied in order to meet the performance requirements and compactness in automotive air conditioning systems. Experimental and simulation study focusing on the air side thermal hydraulic performance of automotive heat exchangers were performed in this article. Test results showed that the heat capacity of a condenser with 5.4 mm height louvered ...
In March 2008, Keppel Seghers started the engineering, supply, construction and commissioning of a Combined Heat and Power (CHP) Waste-to-Energy (WtE) plant in Åmotfors (Sweden). When completed in 2010 the plant will process close to 74,000 tons per year of household waste (average LHV = 10.5 MJ/kg) and limited quantities of (demolition) wood resulting in a yearly production of about 108,700 MW...
In this paper, the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby preve...
This work focused on a compound PV/T waste heat driven ejector-heat pump system for simultaneous data centre cooling and recovery district heating. The uses as the generator’s source, acting with vapour generated in an evaporative condenser ejector drive force. Conventional advanced exergy exergoeconomic analyses are used to determine cause avoidable degree of components’ destruction rate cost ...
Due to the necessity to achievement of heat pump manufacturing technology as an important step in the development of geothermal systems, a heat pump is designed, manufactured and analyzed in different operating conditions. The heat pump is water to water type which is extensively used for heating buildings in winter. A sample of a heat pump from a famous manufacturer is selected to dissemble an...
Abstract: The diameter and configuration of tubes are important design parameters of power condensers. If a proper tube diameter is applied during the design of a power unit, a high energy efficiency of the condenser itself can be achieved and the performance of the whole power generation unit can be improved. If a tube assembly is to be replaced, one should verify whether the chosen condenser ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید