Schizophrenia and bipolar disorder are disorders characterized by alterations in cellular molecular mechanisms. Annexin A3 (ANXA3) has various effects on neural mechanisms membrane phospholipid function both thought to be associated with psychotic disorders. Our study consisted of 93 schizophrenia 52 healthy controls. ANXA3 was analyzed enzyme-linked immunosorbent assay (ELISA). levels were sig...
Endogenous creatinine clearance (Ccr) is widely accepted as an estimate of glomerular filtration rate (GFR), the best overall biomarker of kidney function. However, current common methods of measuring creatinine are not sensitive enough for mouse plasma. Accordingly, we here report a new method of measuring creatinine by liquid chromatography tandem mass spectrometry (LC-MS/MS) using deuterated...
Background: The peritoneal equilibration test involves measurement of creatinine, in blood and dialysate, to assess efficacy dialysis treatment, therefore requires accurate precise measurements. Several exogenous or endogenous substances interfere with some creatinine measurements, including high glucose fluid formulations. Methods: An interference study was performed by evaluating spiked recov...
We describe an improved enzymatic ultraviolet absorbance method for assaying creatinine in serum, plasma, and urine. Creatinine is hydrolyzed by creatinine iminohydrolase (EC 3.5.4.21) to ammonia and N-methylhydantoin. The ammonia produced combines with 2-oxoglutarate and NADPH in the presence of glutamate dehydrogenase to yield glutamate and NADP+. The consumption of NADPH, measured by a two-p...
We describe a new dip- and read dipstick that detects urine albumin at concentrations of 10 mg/l and above and urine creatinine at concentrations of 300 mg/l and above. The albumin assay is based on a high-affinity, dye-binding technique while the creatinine assay is based on the peroxidase-like activity of copper creatinine complexes. With these two-test dipsticks, urines from normal adults su...
BACKGROUND Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigati...
Creatinine is widely used as an indirect marker of renal function. However, interfering factors such as diet, exercise and problems with the assay can generate false results and misinterpretation of real kidney function. In this article, we report the dietary effects on serum creatinine during a phase I single dose escalation study and discuss the reasons why serum creatinine should be measured...
objective(s) comparison of prooxidant-antioxidant balance (pab) assay with crocin assay. materials and methods twenty eight serum samples were chosen, pab and the total antioxidant capacity were measured by pab assay and crocin, respectively, and the correlation of both assays, along with their correlation with other clinical and biochemical parameters, were determined. results a significant ne...