Journal: :journal of artificial intelligence in electrical engineering 0
parisaalipour alipour department of engineering, ahar branch, islamic azad university, ahar, iran mahdisalimi salimi department of engineering, ardabil branch, islamic azad university, ardabil, iran

in this paper, a novel control method for photovoltaic converter connection to the national gridis presented, so in addition to the injection control by solar arrays to the grid, this method cancompensate reactive power and harmonics in the load current. the system will be connected inparallel between the grid and load. the proposed system supplies all load power consumption(including active po...

2016
U. Sri Anjaneyulu B. Srinivasa Rao P. Guruvulu Naidu

Renewable Energy Sources (RES) are nowadays growing rapidly at the distribution level and it employs power electronic converters to ensure reliable operation to the customers. Among the RES, wind energy is now firmly established technology for electricity generation. This paper proposes a conventional PI controller and Artificial Neural Network (ANN) controller to GSC of PMSG, which can obtain ...

1998
Timothy M. Whalen Jr-Shiuan Yang

Design speci cations for wind loads on low-rise structures still rely on reductive tables and plots that can over-simplify the highly complex nature of wind-structure interaction. The need for simpli ed information and design procedures stems in part from the limited information capacity of the current generation of design standards. The purpose of the present study is to demonstrate a prototyp...

2016

Meenakumari.S Department of Electrical and Electronics Engineering,Er.Perumal Manimekalai College of Engineering, Hosur, India Abstract— In this project, a near-unity-power-factor front-end rectifier employing two current control methods, namely, average current control and hysteresis current control, is considered. This rectifier is interfaced with a fixed-pitch wind turbine driving a permanen...

D. Yu L. Hongjun L. Junnan L. Yalei X. Dapeng X. Lixiong Y. Zhanxin Z. Fang

For economic benefit of wind power generation, the equivalent conversion relationships and models between the different “quality” energy are studied deeply in the conversion processes of wind energy. Considering the effect of load demand characteristics and energy supply price on the wind energy utilization mode comprehensively, the multi-objective trans-utilization optimization model of wind e...

2008
Hannele Holttinen Michael Milligan Brendan Kirby Tom Acker Viktoria Neimane Tom Molinski

The variability inherent in wind power production will require increased flexibility in the power system, when a significant amount of load is covered with wind power. Standard deviation (σ) of variability in load and net load (load net of wind) has been used when estimating the effect of wind power on the short term reserves of the power system. This method is straightforward and easy to use w...

2015
M. G. Sugirtha P. Latha

In modern electrical distribution systems harmonic distortions are created from a number of sources such as variable frequency drives, lighting, computers and nonlinear loads. Such harmonic distortions produce a variety of undesirable side effects ranging from poor power factor, motor failure to overloading of transformers and conductors. Now a days increasing number of renewable energy systems...

2015
Weifei Hu K. K. Choi Hyunkyoo Cho Nicholas J. Gaul Olesya I. Zhupanska

1. Abstract Conventional wind turbine blades have been designed using fatigue life predictions based on a fixed wind load distribution that does not fully capture uncertainty of the wind load. This could result in early fatigue failure of blades and eventually increase the maintenance cost of wind turbines. To produce reliable as well as economical wind turbine blades, this paper studies reliab...

2011
Krish Narendra

Wind farms are generally located far away from load centers and, to increase the power flow, series capacitors are normally installed to compensate the transmission line reactance. The interaction of the series capacitor with the wind system can cause undamped sub-harmonic (below 60 Hz or 50Hz system frequency) current and voltage oscillations, which can cause serious damage to wind turbine con...

2004
Xinzhong Chen Ahsan Kareem

In current design practice, spatiotemporally varying wind loads on buildings are modeled as equivalent static wind loads. This loading description serves as pivotal information for estimating response under the combined action of wind and other loads. This paper presents a framework for evaluating the equivalent static wind load for any given peak response of buildings with uncoupled responses ...