نتایج جستجو برای: current transformer saturation

تعداد نتایج: 831636  

2015
D. Vidal J. Pedra

Airport ground lighting (AGL) systems provide visual reference to aircrafts during airport operations. In AGL systems, constant current regulators feed a beacon circuit supplied through isolation transformers. Component modeling is necessary to simulate AGL systems, and thus characterize and predict their behavior. This paper presents an isolation transformer model including transformer core sa...

2012
D P BALACHANDRAN R SREERAMA KUMAR B JAYANAND

During the transient period at the start of transformer energization, it experiences a flux linkage that is up to twice its nominal steady state value and saturates the core. This causes a large inrush current to flow which affects the power system stability and power quality especially when the source is weak. Sequential phase energization technique and addition of neutral resistor are the maj...

Journal: :Renewable energy & power quality journal 2021

In the first part of paper detailed analysis existing current transformer (CT) saturation detection methods with their classification is presented. A new method has been proposed in second paper. Mathematical description given. next section a CT model test scheme To identify reliability against nose and remanent flux density experiments have produced fourth section. Comparative between also Fin...

2001
Seong-Jeub Jeon Gyu-Hyeong Cho

A new primary-side-assisted zero-voltage and zerocurrent switching full bridge dc–dc converter with transformer isolation is proposed. The proposed dc–dc converter uses only one auxiliary transformer and two diodes to obtain ZCS for the leading leg. It has a simple and robust structure, and load current control capability even in short circuit conditions. Possibility of magnetic saturation due ...

2001
T. G. Engel

The analysis, design, and operation of high-voltage, transformer-coupled LC vector inversion generators are presented and discussed. The transformer-coupled LC inversion generator is easy to construct and, compared with Marx-type generators and conventional LC vector inversion generators, requires only one inversion switch, independent of the number of voltage multiplication stages. The transfo...

2015
F. A. Pereira F. C. F. Guerra U. A. Carmo

A platform implemented with Digital Signal Controllers (DSCs) developed for real time studies of the dynamic behavior of the air-gapped current transformers (CTs) used in power grid protection and measurement systems is presented. The implemented algorithms simulate the fault current in an electric power system as well as the transient response of the current transformer. It is also presented a...

2000
M M Saha J Izykowski M Lukowicz E Rosolowski

Current and voltage transformers influence the criterion values measurement particularly during disturbances in the system. Certain construction limitations of instrument transformers may in some cases cause maloperation or substantial delay in tripping of the protective relays. Current transformer saturation and discharging of the capacitive voltage transformer’s internal energy during short c...

2011
Vladimir Gurevich V. Gurevich

The article examines the problem of saturation and failure of power transformers under geomagnetically induced currents and currents of the E3 component of high-altitude nuclear explosions. It also describes a special protective relay reacting on DC component in the transformer neutral current.

Journal: :نشریه دانشکده فنی 0
حسین محسنی فرامرز رهبر

usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...