Introduction: Irregular/blocked fields are routinely used in radiotherapy. The doses of these fields are usually calculated by means of equivalent square method that is inherently prone to uncertainty. On the other hand, Clarkson’s sector integration method is a dose calculation method which offers far better accuracy in dose calculation of irregular fields. The Scatter Air Ratio (SAR) of an in...

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...

M. Ghorbani M. J. Tahmasebi Birgani

Introduction:  On  the  basis  of  percent  depth  dose  (PDD)  calculation,  the  application  of  dosimetry  in  radiotherapy  has  an  important  role  to  play  in  reducing  the  chance  of  tumor  recurrence. The aim of this study is to introduce a new formula for calculating the centeral axis  percent depth doses of Cobalt-60 beam.   Materials and Methods: In the present study, based on ...

Ali Shabestani Monfared Mehrangiz Amiri

  Introduction: Radioactive materials deliver internal radiation dose to patients in nuclear medicine. Manual internal radiation dose assessment is a complicated method. Introduction of a simple dose calculation software is the main goal of the present study. Methods: Using the best current data in internal dose calculation (S-Factors) recommended by ICRP and by cons...

Journal: :Journal of Environmental Engineering (Transactions of AIJ) 2016

Journal: :Indian Journal of Psychiatry 2010

Journal: :iranian journal of medical physics 0
ali asghar mowlavi associate professor, physics dept., school of sciences, sabzevar tarbiat moallem university, sabzevar, iran.

introduction: average glandular dose calculation in mammography with mo-rh target-filter and dose calculation for different situations is accurate and fast. material and methods: in this research, first of all, x-ray spectra of a mo target bombarded by a 28 kev electron beam with and without a rh filter were calculated using the mcnp code. then, we used the sobol-wu parameters to write a fortra...

Journal: :iranian journal of medical physics 0
m. j. tahmasebi birgani associate professor, medical physics dept., ahwaz university of medical sciences, ahwaz, iran. m. ghorbani ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran.

introduction:  on  the  basis  of  percent  depth  dose  (pdd)  calculation,  the  application  of  dosimetry  in  radiotherapy  has  an  important  role  to  play  in  reducing  the  chance  of  tumor  recurrence. the aim of this study is to introduce a new formula for calculating the centeral axis  percent depth doses of cobalt-60 beam.   materials and methods: in the present study, based on ...