نتایج جستجو برای: dosimetric audit absolute photon dose linacs

تعداد نتایج: 491847  

Ehsan Mohammadi Hasan Nedaie Mahbod Esfehani, Mahdi Aghili Mahmood Allahverdi Seyed Ali Vaezzadeh

Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...

2014
So-Yeon Park Beom Seok Ahn Jong Min Park Sung-Joon Ye Il han Kim Jung-in Kim

BACKGROUND In this study, dosimetric aspects of TSEI consisting of a 4 MeV beam with no spoiler were investigated in comparison to a nominal 6 MeV beam with spoiler, and the potential for clinical applications was evaluated. METHODS The TSEI technique is based on the Stanford technique, which utilizes a beam configuration of six-dual fields. MOSFETs were used to measure the optimal gantry ang...

du Plessis, F.C.P., Setilo, I.,

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, madurai medical college and govt. rajaji hospital, maduari-625 020, india

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

Journal: :Medical physics 2002
M Bucciolini S Russo F Banci Buonamici S Pini P Silli

A 6 MV photon beam from Linac SL75-5 has been collimated with a new micromultileaf device that is able to shape the field in the two orthogonal directions with four banks of leaves. This is the first clinical installation of the collimator and in this paper the dosimetric characterization of the system is reported. The dosimetric parameters required by the treatment planning system used for the...

2015
Robert A. Corns Vicky W. Huang Steven D. Thomas

Flattening filter-free radiation beams have higher dose rates that significantly increase the ion recombination rate in an ion chamber's volume and lower the signal read by the chamber-electrometer pair. The ion collection efficiency correction (P(ion)) accounts for the loss of signal and subsequently changes dosimetric quantities when applied. We seek to characterize the changes to the percent...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

2010
Savino Cilla Andrea Fidanzio Francesca Greco Domenico Sabatino Aniello Russo Laura Gargiulo Luigi Azario Angelo Piermattei

In-vivo dosimetry techniques are currently being applied only by a few Centers because they require time-consuming implementation measurements, and workload for detector positioning and data analysis. The transit in-vivo dosimetry performed by the electronic portal imaging device (EPID) avoids the problem of solid-state detector positioning on the patient. Moreover, the dosimetric characterizat...

2015
Ying Zhang Yuanming Feng Munir Ahmad Xin Ming Li Zhou Jun Deng Qinghui Zhang

The goal of this study is to evaluate the effects of intermediate megavoltage (3-MV) photon beams on SBRT lung cancer treatments. To start with, a 3-MV virtual beam was commissioned on a commercial treatment planning system based on Monte Carlo simulations. Three optimized plans (6-MV, 3-MV and dual energy of 3- and 6-MV) were generated for 31 lung cancer patients with identical beam configurat...

2015
J. H. Lee L. T. Chang A. C. Shiau C. W. Chen Y. J. Liao W. J. Li M. S. Lee S. M. Hsu

A standard protocol of dosimetric measurements is used by the organizations responsible for verifying that the doses delivered in radiation-therapy institutions are within authorized limits. This study evaluated a self-designed simple auditing phantom for use in verifying the dose of radiation therapy; the phantom design, dose audit system, and clinical tests are described. Thermoluminescent do...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید