Journal: :basic and clinical cancer research 0
narges jooladi tehran university of medical sciences, tehran, iran seyed rabee mahdavi iran university of medical sciences, tehran, iran hasanali nedaei shahid beheshti university of medical sciences, tehran, iran hasan nosrati shahid beheshti university of medical sciences, tehran, iran mansour naderi tehran university of medical sciences, tehran, iran mahbod esfehani tehran university of medical sciences, tehran, iran

background : this study was set to determine the optimal technique of breast cancer with supraclavicular fossa irradiation. methods : three techniques was compared in this study. techniques were two point symmetric (2p-sym), two point asymmetric (2p-asym) and single point (sp). in 2p-sym all of beams were symmetric, in 2p-asym tangential beams were symmetric and supra was asymmetric, in sp all ...

Journal: :International Journal of Chemical Engineering and Applications 2013

2015
Christos Antypas Ioannis Floros Maritina Rouchota Christina Armpilia Maria Lyra

The accuracy of MLC positions during radiotherapy is important as even small positional deviations can translate into considerable dose delivery errors. This becomes crucial when radiosensitive organs are located near the treated volume and especially during IMRT, where dose gradients are steep. A test commonly conducted to measure the positional accuracy of the MLCs is the Picket Fence test. I...

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

2014
Richard E. Wendt

Radiochromic film with a dye incorporated into the radiation sensitive layer [Gafchromic EBT2, Ashland, Inc.] may be digitized by a color transparency scanner, digitally processed, and calibrated so that a digital image in units of radiation absorbed dose is obtained. A transformation from raw scanner values to dose values was developed based upon a principal component analysis of the optical d...

2013
Sei-Kwon Kang Soah Park Taejin Hwang Kwang-Ho Cheong Taejin Han Haeyoung Kim Me-Yeon Lee Kyoung Ju Kim Do Hoon Oh Hoonsik Bae

Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as a substitute for a metallic eye shield during CT scans. An acrylic dummy shield of the same size...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2014
M Zarza-Moreno P Carreira L Madureira H Miras Del Rio F J Salguero A Leal N Teixeira A P Jesus G Mora

This study evaluates the dosimetric impact caused by an air cavity located at 2 mm depth from the top surface in a PMMA phantom irradiated by electron beams produced by a Siemens Primus linear accelerator. A systematic evaluation of the effect related to the cavity area and thickness as well as to the electron beam energy was performed by using Monte Carlo simulations (EGSnrc code), Pencil Beam...