نتایج جستجو برای: electron spectrometer
تعداد نتایج: 327383 فیلتر نتایج به سال:
چکیده ندارد.
A novel design for a compact gamma-ray spectrometer is presented. The proposed system allows for spectroscopy of high-flux multi-MeV gamma-ray beams with MeV energy resolution in a compact design. In its basic configuration, the spectrometer exploits conversion of gamma-rays into electrons via Compton scattering in a low-Z material. The scattered electron population is then spectrally resolved ...
INSTRUMENTATION The EnergyDispr5jy Spectrometer The Solid state x-ray detector or energy-dispersive spectrometer (EDS) was 1°Ped in the late l960s and rapidly found use on electron-beam instruments rald er a!., 1968) because of its speed in collecting and simultaneously displaying da from a wide energy range. Its small size, but relatively large collection angle 123 Authors Copy
Recent data taken at the FELIX facility are presented. Losses in the optical cavity have been artificially increased by the introduction of fine wires, and measurements of the resulting optical and electron energy spectra have been made over a range of cavity losses. The experimental data show that the extraction efficiency varies as the inverse square root of the cavity losses, consistent with...
The investigation of the photoelectron-escape mechanism from GaAs cathodes with negative electron affinity requires the detection of very low energy electrons. We have built a novel, UHV-compatible, spectrometer where the photoelectrons are imaged by a homogeneous electric field onto a position-sensitive detector. The time-of-flight of each single emitted electron and its position on the detect...
The first result of the neutrino magnetic moment measurement at the Kalininskaya Nuclear Power Plant (KNPP) with the GEMMA spectrometer is presented. An antineutrino-electron scattering is investigated. A high-purity germanium detector of 1.5 kg placed 13.9 m away from the 3 GW reactor core is used in the spectrometer. The antineutrino flux is 2.73×1013 ν̄e/cm/s. The differential method is used ...
Electron transfer through gas phase ion-ion reactions has led to the widespread application of electron- based techniques once only capable in ion trapping mass spectrometers. Although any mass analyzer can in theory be coupled to an ion-ion reaction device (typically a 3-D ion trap), some systems of interest exceed the capabilities of most mass spectrometers. This case is particularly true in ...
Materials and Methods: All the reagents were received from Sigma Aldrich Chemical Co. and used without further purification. Solvents were purchased from commercial sources and purified by reported protocol.1 Spectroscopy grade solvents were used for physical studies. 1H NMR and 13C NMR experiments were done on a Bruker DPX-400 MHz and 500 MHz NMR machine and all the data were calibrated agains...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید