نتایج جستجو برای: fiberoptic bronchoscope

تعداد نتایج: 3107  

Journal: :International journal of clinical and experimental medicine 2014
Ling Ye Pingliang Yang Yunxia Zuo

A 64-yr-old man was admitted because of repeated pneumonia. Both fiberoptic bronchoscopy and esophagoscopy revealed a large tracheoesophageal fistula (15 mm) in the right posterior trachea 1 cm beyond the carina. Coated nickel-titanium shape memory alloy Y shaped stent was planned to seal this fistula under general anesthesia. We took advantage of laryngeal mask airway to insert the fiberoptic ...

Journal: :Chest 1978
R B Dreisin R K Albert P A Talley M H Kryger C H Scoggin C W Zwillich

We have prospectively analyzed the accuracy of and the rate of complications in 205 consecutive flexible fiberoptic bronchoscopic procedures, as performed us the setting of a teaching hospital. The objectives of the procedure were achieved in 89 percent of the cases, but the yield varied widely among 12 diagnostic and therapeutic subgroups. Except in the case of the peripheral nodule, a maligna...

2013
Eun Kyeong Choi Ji Eun Kim Sa Rah Soh Chang Kyun Kim Wyun Kon Park

The case of a 33-day-old boy with Pierre Robin syndrome using a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation is presented. After induction with sevoflurane, classical reusable laryngeal mask airway (LMA) #1 was inserted and ultrathin fiberoptic bronchoscope (FOB) was passed through. A Cook® airway exchange catheter (1.6 mm ID, 2.7 mm OD) was passed throug...

Journal: :Middle East journal of anaesthesiology 2011
Lale Karabiyik Emine Altinay Nurdan Bedirli

During insertion of the double lumen tube in patients with ankylosing spondylitis, cervical neutral position should be maintained to avoid vertebral and spinal injuries. Although flexible fiberoptic bronchoscopic intubation is the gold standard, available FOB size is not compatible with that of the endobronchial lumen of the double lumen tube. This problem should be solved according to institut...

Journal: :Chest 1989
S Caglayan I Coteli U Acar S Erkin

A case of sudden onset of severe respiratory distress is reported. Appropriate clinical and roentgenologic findings suggested foreign body aspiration. The foreign body was removed by fiberoptic rigid bronchoscope. Bronchoscopic, histopathologic, and microbiologic findings revealed that the foreign body was a granulomatous mass originating from endobronchial tuberculosis.

Journal: :Chest 1989
H Saito H Saka S Sakai K Shimokata

Transbronchial lung biopsy performed on a 51-year-old woman for the evaluation of nodular densities with cavities in the bilateral apical areas was complicated by the breakage of the biopsy forceps. The broken fragment of the forceps was successfully retrieved by use of the magnetic extractor through a fiberoptic bronchoscope under fluoroscopic guidance.

Journal: :Chest 1991
M Antonelli F Cicconetti G Vivino A Gasparetto

A tracheoesophageal fistula was successfully closed with a fibrin adhesive applied by means of a fiberoptic bronchoscope, instead of by esophagoscopy. To facilitate closure of the fistula, the technique was combined with decontamination of the oral cavity, to avoid bacterial contamination. The procedure is proposed as an alternative to surgery for critically ill patients.

Journal: :archives of anesthesiology and critical care 0
morteza hashemian kerman university of medical sciences sadra samadi department of anesthesiology and pain medicine, kerman university of medical sciences, kerman seyed amir mohajerani shahid beheshti university of medical sciences

awake intubation is the choice for airway management in anticipated difficult airway (da), which means establishing airway without induction of deep sedation; however, in cases where sedation is precarious, decision in emergency situations, success in awake intubation is dependent on proper regional airway block. a 21 year old man with bilateral temporo-mandibular ankyolosis and a 25 years old ...

نمودار تعداد نتایج جستجو در هر سال