Genghua Cao Datong Zhang Weiwen Zhang Wen Zhang

Corrosion behavior of friction stir processing (FSP) WE43 alloy in a simulated body fluid (SBF) was investigated. Micro-galvanic corrosion was the dominated corrosion behavior, and the corrosion resistance of FSP WE43 alloy was improved compared to the cast counterpart. Furthermore, due to the fine-grained and homogeneous microstructure, uniform corrosion morphology was observed on FSP WE43 all...

2012
Indranath Dutta Leslie R. Elkin

continue on reverse if necessary and identify by block number) The corrosion mechanisms and behavior of a P-130x graphite fiber reinforced 6063 aluminum composite laminate were udied. Electrochemical and total immersion tests were performed on the composite in 3.5% sodium chloride and 5.0% >dium sulfate solutions. The effects of pH, the presence of sulfite ions, various heat treatments, and ele...

2017
Peng Hou Pei Han Changli Zhao Hongliu Wu Jiahua Ni Shaoxiang Zhang Jingyi Liu Yuanzhuang Zhang Haidong Xu Pengfei Cheng Shen Liu Yufeng Zheng Xiaonong Zhang Yimin Chai

Magnesium is a type of reactive metal, and is susceptible to galvanic corrosion. In the present study, the impact of coexistence of Ti on the corrosion behavior of high purity Mg (HP Mg) was investigated both in vitro and in vivo. Increased corrosion rate of HP Mg was demonstrated when Mg and Ti discs were not in contact. The in vivo experiments further confirmed accelerating corrosion of HP Mg...

Journal: :Analytical chemistry 2002
Sabine Szunerits David R Walt

The localized corrosion behavior of a galvanic aluminum copper couple was investigated by in situ fluorescence imaging with a fiber-optic imaging sensor. Three different, but complementary methods were used for visualizing remote corrosion sites, mapping the topography of the metal surface, and measuring local chemical concentrations of H+, OH-, and Al3+. The first method is based on a pH-sensi...

2002
William J. Clark Jeremy D. Ramsey Richard L. McCreery Gerald S. Frankel

The effects of chromate treatment on the corrosion of an aluminum/copper aircraft alloy were examined with a galvanic corrosion apparatus composed of two electrodes and a zero resistance ammeter. Combinations of pure Al, pure Cu, and AA2024-T3 electrodes were immersed in 0.1 M NaCl solution, which was saturated with air, O2 , or argon. Selection of electrode material or differential aeration re...

Journal: :Entropy 2014
Zhi Tang Lu Huang Wei He Peter K. Liaw

The effects of metallurgical factors on the aqueous corrosion behavior of highentropy alloys (HEAs) are reviewed in this article. Alloying (e.g., Al and Cu) and processing (e.g., heat treatments) effects on the aqueous corrosion behavior of HEAs, including passive film formation, galvanic corrosion, and pitting corrosion, are discussed in detail. Corrosion rates of HEAs are calculated using ele...

2017
Jichao Li Hugo F. Lopez

The heterogeneous structure of Al alloys renders them susceptible to localized corrosion due to the different electrochemical properties existing in the Al-rich solid solution matrix and secondary phase particles. The galvanic interactions between these two phases can result in pit formation either through dissolution of the particles or corrosion of the matrix adjacent to the particles. This d...

Journal: :The Journal of arthroplasty 2014
Trevor C Gascoyne Richard M Dyrkacz Thomas R Turgeon Colin D Burnell Urs P Wyss Jan-M Brandt

Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from ...

2015
Kimata

Because of the risk of galvanic corrosion, combination use of different metals is supposed to be prohibited in in-vivo environment. Ti-6Al-4V (Ti64) has been use for biomaterials due to its good biocompatibility [1-3]. Therefore, the combination use with the conventional stainless steel of SUS316L (SUS) is increasing due to accidental misuse in emergency cases or necessary choice of stainless w...

2013
L. Lacroix

Study of the corrosion behaviour of a magnetron sputtered Al–Cu/Al–Cu–Mg model alloy couple in sulphate solutions has been undertaken to gain insight into the galvanic coupling between the matrix and SAl2CuMg particles in the 2024 aluminium alloy (AA2024). Polarisation curves and local electrochemical impedance spectroscopy measurements (LEIS) were performed on the individual alloys and on the ...