نتایج جستجو برای: goldmann

تعداد نتایج: 1075  

Journal: :The British journal of ophthalmology 1976
G A Fishman L M Jampol M F Goldberg

Extensive retinal vascular disease was noted in three patients from two families with Favre-Goldmann syndrome. In addition to classical features they had pronounced leakage from some retinal vessels. Vessels were either opaque ('sclerotic') or non-perfused. Cystoid macular oedema was a contributing cause of decreased vision. Two of the three patients showed a discrepancy on electroretinography ...

2017
Seung Pil Bang Chong Eun Lee Yu Cheol Kim

Title: Comparison of Intraocular Pressure as Measured by Three Different Non-contact Tonometers and Goldmann Applanation Tonometer for Non-glaucomatous Subjects Authors: Seung Pil Bang ([email protected]) Chong Eun Lee ([email protected]) Yu Cheol Kim ([email protected]) Version: 3 Date: 27 Jul 2017 Author’s response to reviews: Revision Letter Manuscript Number BOPH-D-17-00287 “Comparison of Int...

Journal: :Acta Ophthalmologica Scandinavica 1999

Journal: :The British journal of ophthalmology 2004
A C Browning A Bhan A P Rotchford S Shah H S Dua

BACKGROUND/AIM To compare intraocular pressure (IOP) measurements taken by the Goldmann applanation tonometer, the Tono-Pen and the ocular blood flow pneumotonometer in eyes with varying central corneal thickness (CCT) due to penetrating keratoplasty (PK), keratoconus (KC), and Fuchs' endothelial dystrophy (FED). METHODS IOP was measured with the Goldmann applanation tonometer, Tono-Pen XL, a...

Journal: :The British journal of ophthalmology 2003
J B Jonas

BACKGROUND To assess the reproducibility of ophthalmodynamometric measurements using a new, Goldmann contact lens associated, device allowing biomicroscopic visualisation of the optic disc. METHODS The prospective clinical study included 87 eyes of 58 subjects presenting with a normal fundus (n=40), or ocular diseases (n=47). With topical anaesthesia, a Goldmann contact lens, fitted with a pr...

2014
Fiona J. Rowe Alison Rowlands

PURPOSE To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. METHODS Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of ...

Journal: :Investigative ophthalmology & visual science 2002
Archana Bhan Andrew C Browning Sunil Shah Robin Hamilton Dinesh Dave Harminder S Dua

PURPOSE To compare intraocular pressure (IOP) measurements of the Ocular Blood Flow (OBF) pneumotonometer, Goldmann applanation tonometer, and Tono-Pen in eyes with normal corneas of various thicknesses. METHODS IOP was measured with an OBF pneumotonometer, Tono-Pen and Goldmann applanation tonometer in random order in 181 eyes with normal corneas. Central corneal thickness (CCT) was measured...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید