نتایج جستجو برای: hip prosthesis

تعداد نتایج: 88373  

Journal: :Collegium antropologicum 2007
Gordan Gulan Hari Jurdana

The Müller type cemented hip prosthesis, also called self-locking prosthesis, is one of the most extensively copied and utilized hip prostheses. Considering the implantation of the cemented stem, the author originally suggested achieving a press fit between the stem and endostal cortex by implanting a prosthesis of the largest possible size. Analyzing our group of patients who undergo aseptic s...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2003
C Liu S M Green N D Watkins P J Gregg A W McCaskie

A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemente...

Journal: :The Medical journal of Australia 2004
John A L Hart

Joint replacement is the most effective healthcare measure in improving patient quality-of-life outcomes. More than 46000 hip and knee replacements were performed in Australia between July 2000 and July 2001. The need for joint replacements will increase as the population ages. More than 90% of hip and/or knee replacements survive for 10-15 years. Prosthesis selection needs to be tailored to ea...

Journal: :International journal of clinical and experimental medicine 2014
Xiao-Mei Ma Chun-Yan Xia Pei-Liang Fu Hui-Min Liu Hong-Yu Yu Jin He

Pigmented Villonodular Synovitis (PVNS) is a relatively rare, benign proliferation lesion of the synovium of large joints. The etiology is varied and unclear. We had report a 79-year-old woman had PVNS after 14 years right hip arthroplasty with metal prosthesis. Here we report another 4 patients had PVNS after arthroplasty. The second one had PVNS in the 2(th) year after hip arthroplasty with b...

Journal: :Wearable technologies 2023

Abstract This article proposes, describes, and tests a swing-assist walking controller for stance-controlled, swing-assisted knee prosthesis that aims to combine benefits of passive swing mechanics (e.g., quiet operation, biomimetic function, low power requirements) with powered assistance increased robustness swing-phase motion specifically toe clearance). A three-participant, multislope, mult...

Journal: :Acta medica Okayama 2002
Isagi Mizuta Hiroo Fujiwara Hajime Inoue

Postoperative hip alignment was studied on radiographs in cases of total hip arthroplasty (THA) and of Bipolar Head Prosthesis(BHP), both with MX-1. Postoperative anteroposterior-view radiographs of hip joints of patients with a normal hip joint on the unoperated side and without pelvic tilt were used. Thirty-nine THA patients (femoral neck fracture), 26 THA patients (osteonecrosis of the femor...

Journal: :Orthopedics 2004
Masayoshi Yagi Tetsuhiro Iguchi Katsuhito Ichimura Akira Kurihara Koichi Kasahara Shinichi Yoshiya

Bipolar hemiarthroplasty of the hip joint has been used for the treatment of femoral neck fractures and osteonecrosis of the femoral head.1-2 This prosthesis originally was believed to decrease shear stress on the acetabular cartilage, resulting in decreased migration.3,4 However, osteolysis of the acetabulum and migration of the head have been reported after bipolar hemiarthroplasty.5-7 This a...

2014
Chengdong Piao Dankai Wu Min Luo Hongshun Ma

OBJECTIVE The study aims to compare the stress shielding effects of implantable anatomical and traditional prostheses after in vitro total hip joint replacement simulation. The study serves as a biomechanical basis for novel artificial prostheses and for clinical hip joint replacements. METHODS Sixteen femoral specimens from adult male corpses were randomly divided into two groups: the tradit...

2014
Abdul Halim Abdullah Mitsugu Todo

Stress shielding and bone remodeling effects are critical issues in promoting long term stability of Total Hip Arthroplasty (THA). Stress shielding occurs when the femur experiences less stress after the presence of the prosthesis stem. In this study, biomechanical evaluations of lower limbs are established using the finite element method in corresponding to stress distributions. Lower limbs CT...

Journal: :Ortopedia, traumatologia, rehabilitacja 2005
Marek Bozek Tadeusz Szymon Gaździk Justyna Kotas-Strzoda Marek Kaleta Jacek Szpunar

Background. The goal of our study was to assess the efficacy of total hip replacement in the treatment of dysplastic arthrosis of the hip. Material and methods. Between November 2001 and June 2003 we performed total hip replacement in 40 patients (46 hips). Arthritic deformations were classified according to Crowe's classification scheme and operated using a variety of techniques and prostheses...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید