Contact dermatitis after implantable cardiac defibrillator implantation for ventricular tachycardia.
Pacemaker contact sensitivity is a rare condition. Less than 30 reports of pacemaker skin reactions have been described. We report a 57-year-old woman who underwent an implantable cardiac defibrillator (ICD) implantation for ventricular tachycardia. A skin patch test was positive on almost all components of the pacemaker system. She was treated with topical corticosteroids and skin lesions reso...
BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...
Damage to the coronary arteries and related structures from pacemaker and implantable cardioverter-defibrillator lead implantation is a rarely reported complication that can lead to myocardial infarction and pericardial tamponade that may occur acutely or even years later. We summarize the reported cases of injury to coronary arteries and related structures and review the causes of troponin ele...
Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this st...
Theoretical and experimental studies are conducted on the electromagnetic field (EMF) distributions excited inside train carriages and the implantable cardiac pacemaker EMC issue in the same environment. Both precise computer simulations and experiments using 800 MHz and 2 GHz transmitters in an actual train carriage confirm that excessively high EMF, high enough to affect pacemaker normal func...
Twiddler’s syndrome is a rare condition caused by coiling of the leads, leading to malfunction in pacemaker or automated implantable cardioverter-defibrillator (AICD). It was first described Bayliss 1968 as rare, but potentially fatal complication treatment1. Inappropriate shocks due malfunctioning AICD can be devastating, traumatic, patient.
BACKGROUND We sought to determine the potential of right ventricular VVI backup pacing to induce ventricular tachyarrhythmias in patients with implanted cardioverter-defibrillators. METHODS AND RESULTS All consecutive patients presenting exclusively with pacemaker-induced tachycardias (PITs) were included in a prospective study using a crossover protocol. Patients were randomized to either gr...
Batteries used in Implantable cardiac pacemakers-present unique challenges to their developers and manufacturers in terms of high levels of safety and reliability. In addition, the batteries must have longevity to avoid frequent replacements. Technological advances in leads/electrodes have reduced energy requirements by two orders of magnitude. Micro-electronics advances sharply reduce internal...
Accurate knowledge ofpacemaker specifications provides the key to the understanding of complex demand pacemaker arrhythmias. This communication describes two examples of complex pacemaker arrhythmias related to the sensing mechanism of normally functioning Medtronic demand pulse generators. Oversensing of atrial voltage generated by an atrial parasystolic focus produced the first arrhythmia. Th...