Journal: :Medical physics 2004
S Amerio A Boriano F Bourhaleb R Cirio M Donetti A Fidanzio E Garelli S Giordanengo E Madon F Marchetto U Nastasi C Peroni A Piermattei C J Sanz Freire A Sardo E Trevisiol

A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is ...

Journal: :Medical physics 2011
James A Tanyi Kevin D Nitzling Camille J Lodwick Alan L Huston Brian L Justus

PURPOSE Assessment of the fundamental dosimetric characteristics of a novel gated fiber-optic-coupled dosimetry system for clinical electron beam irradiation. METHODS The response of fiber-optic-coupled dosimetry system to clinical electron beam, with nominal energy range of 6-20 MeV, was evaluated for reproducibility, linearity, and output dependence on dose rate, dose per pulse, energy, and...

2002
J. S. Wang R. Wada K. Hagel D. Shetty Y. Ma L. Qin M. Murray A. Makeev P. Smith J. B. Natowitz T. Keutgen

NIMROD is a nearly 4pi detector system that consists of a 4pi neutron ball, 96 Ionization Chamber-Si-CsI modules in the forward 8 rings from 3.6 degree to 47 four rings with 46 CsI, Ionization Chamber and several Si detectors covering backward angles theta from 47 degrees to 170 degrees, four rings with 46 CsI, Ionization Chamber and several Si detectors covering backward angles theta from 47 d...

Journal: :Review of Scientific Instruments 1956

Journal: :Transactions of the Society of Instrument and Control Engineers 1969

Journal: :Iraqi Journal of Physics (IJP) 2019

Journal: :IEEE Transactions on Nuclear Science 1980

2012
N. A. COSTA M.P.A. POTIENS

The kerma-area product (PKA) is a useful quantity to establish the reference levels in diagnosis of conventional X ray examinations. A KAP meter can be calibrated in laboratory or in situ, where it is used. The patient dose calibrator (PDC) is a new equipment from Radcal that measures PKA. It was manufactured following the IEC 60580 recommendations. The aim of this study was to calibrate the PD...

Journal: :Nuclear Instruments and Methods in Physics Research 1984

2003
C. N. DE SOUZA L. V. E. CALDAS t C. H. SIBATA A. K. HO K. H. SHIN

-Two parallel-plate ionization chambers were projected, constructed and evauated for use in high energy electron beams. They were constructed using the two plastic materials recommended for clinical dosimetry protocols, i.e. acrylic and polystyrene. Both chambers have cylindrical shape with entrance windows in aluminized Mylar and they are open to the air. The acrylic chamber has a 2 mm air gap...