نتایج جستجو برای: isolated aortic regurgitation

تعداد نتایج: 446631  

Journal: :European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2006
Henning F Lausberg Diana Aicher Frank Langer Hans-Joachim Schäfers

INTRODUCTION Isolated aortic valve repair (AVR) has been gaining increasing interest in recent times. Results of isolated aortic valve repair have been reported to be variable. Various techniques have been utilized. We analyzed our experience with isolated valve repair using autologous pericardial patch plasty and compared the results to an age-matched collective with aortic valve repair withou...

Journal: :British heart journal 1984
N L DePace P F Nestico M N Kotler G S Mintz D Kimbiris I P Goel E E Glazier-Laskey J Ross

To assess the accuracy of echocardiography in determining the cause of aortic regurgitation M mode and cross sectional echocardiography were compared with angiography in 43 patients with predominant aortic regurgitation. Each patient had all three investigations performed during the same admission to hospital. In each instance, the cause of aortic regurgitation was confirmed at surgery or necro...

Journal: :European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology 2008
Sridevi R Pitta Ashok Kondur Luis Afonso

Quadricuspid aortic valve is a rare congenital anomaly. It may present as an isolated anomaly but is occasionally associated with aortic regurgitation. Sinus of Valsalva aneurysm (SVA) is also an infrequent congenital anomaly, typically associated with tricuspid aortic valves. There are only a few reported cases of SVA (ruptured) associated with quadricuspid aortic valves in the literature. We ...

M BORZOOE, M.B TABATABAEI,

A seven-year-old girl with clinical diagnosis of aortic insufficiency underwent echocardiographic and hemodynamic evaluation and referred for surgery with the same diagnosis. However, at surgery, aorto-Ieft ventricular tunnel was found and repaired successfully. Review of echocardiogram and catheterization data revealed interesting findings to differentiate this rare entity from congenital...

Journal: :The Journal of the Association of Physicians of India 2015
Ashok Garg Vikram Goyal Manish Bansal

A 60 years old lady presented to our institute with complains of progressive dyspnea on exertion, increasing from New York Heart Association functional class II to class III over last 2-3 months. She did not have any history of fever, chest pain, palpitations, presyncope or syncope. On examination, her pulse rate was 90 per minute regular and the blood pressure was 130/60 mm Hg. Rest of the gen...

Journal: :Heart 2002
Y Miyake T Hozumi I Mori K Sugioka A Yamamuro T Akasaka S Homma K Yoshida J Yoshikawa

BACKGROUND The recently introduced automated cardiac flow measurement (ACM) technique provides a quick and an accurate automated calculation of stroke volume and cardiac output. This is obtained by spatio-temporal integration of digital Doppler velocity profile data. OBJECTIVE To evaluate the use of the ACM method in the non-invasive assessment of aortic regurgitant volume and per cent regurg...

Journal: :Journal of the American College of Cardiology 1986
P C Come M F Riley L V Carl S Nakao

Pulsed Doppler echocardiography was used to determine prospectively the prevalence of mitral, aortic, tricuspid and pulmonary regurgitation in 80 consecutive patients with mitral valve prolapse and 85 normal subjects with similar age and sex distribution. Mitral valve prolapse was defined by posterior systolic displacement of the mitral valve on M-mode echocardiography of 3 mm or more (40 patie...

2005
WEI FENG SHEN

We studied the relationship between myocardial contractile state and left ventricular functional response to exercise in 14 asymptomatic patients with isolated moderate-to-severe aortic regurgitation and six control subjects. The slope of the systolic blood pressure-left ventricular endsystolic volume (pressure-volume) relationship determined by radionuclide ventriculography during angiotensin ...

2002
Y Miyake K Sugioka A Yamamuro T Akasaka S Homma K Yoshida J Yoshikawa

Background: The recently introduced automated cardiac flow measurement (ACM) technique provides a quick and an accurate automated calculation of stroke volume and cardiac output. This is obtained by spatio-temporal integration of digital Doppler velocity profile data. Objective: To evaluate the use of the ACM method in the non-invasive assessment of aortic regurgitant volume and per cent regurg...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید