نتایج جستجو برای: l ascorbic acid determination
تعداد نتایج: 1496572 فیلتر نتایج به سال:
A new and simple flow injection method followed by atomic absorption spectrometry has been developed for the indirect determination of ascorbic acid. The proposed method is based on oxidation of ascorbic acid to dehydroascorbic acid using a solid-phase manganese dioxide (30% m/m suspended on silica gel beads) reactor. The flow of the sample through the column reduces the MnO2 to Mn(II) in an ac...
lism. Severe changes in the concentration of uric acid causes several diseases such as gout, hyperuricemia and Lesch–Nyhan syndrome. Therefore, the accurate determination of uric acid in urine samples can be a powerful indicator of diagnosing diseases. Thus, many researchers have focused to develop a simple, sensitive and accurate method for determining uric acid. Various methods have been deve...
The postharvest life of cut Eustoma grandiflorum flowers is limited in open flowers. Therefore a factorial experiment based on a completely randomized design with ascorbic acid (AsA) at 4 levels (0, 100, 200, 300mg L-1) and citric acid (CA) at 3 levels (0, 100, 200 mg L-1) with 3 replications and 3 samples for each replications, was conducted for this purpose. Results indicated that a significa...
The effects of L-ascorbic acid and its stable analogue L-ascorbic acid 2-glucoside on the restoration of liver mass and recovery of liver function after 70% partial hepatectomy (PH), were compared with other natural vitamin C analogues in rats in vivo. L-Ascorbic acid (100 mg/kg/d, intraperitoneally (i.p.))- and L-ascorbic acid 2-glucoside (50 mg/kg/d, i.p.)-treated rats showed an approximately...
A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...
A simultaneous determination with UV detection/capillary electrophoresis for Fe(II) and Fe(III) was achieved using a sulfonated bathophenantholine and desfferioxamine B. When the electrophoretic buffer was 60 mmol l(-1) SDS, 10 mmol l(-1) acetic acid (pH 4.0) and 10 mmol l(-1) ascorbic acid and at -10 kV, the iron(II) and iron(III) could not only be completely separated, but also be sensitively...
a carbon paste electrode modified with cobalt (ii) phthalocyanine (copc) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. the potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 m (?1- 1800 µg ml ) with a nernstian slope of 56 mv at ph 7. the limit of detection was 0.2 µg ml ascor...
The inhibitory effect of ascorbic acid on Campylobacter jejuni is described. In vitro growth of clinical strains, as measured spectrophotometrically, was inhibited by 0.5 mg of freshly prepared L-ascorbic acid per ml. Alkaline-treated or aged L-ascorbic acid increased inhibition, as did copper; however, L-cysteine, L-cystine, and glutathione prevented inhibition. Biochemical analysis of the med...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید