نتایج جستجو برای: ncat digital phantom gated treatment planning conventionaltreatment planning

تعداد نتایج: 1903689  

2001
Steven M. Kirsner Karl L. Prado Ramesh C. Tailor José A. Bencomo

This report specifically describes the use of a unique anthropomorphic breast phantom to validate the accuracy of three-dimensional dose calculations performed by a commercial treatment-planning system for intact-breast tangential irradiation. The accuracy of monitor-unit calculations has been corroborated using ionization chamber measurements made in this phantom. Measured doses have been comp...

2004
James L. Bedford Peter J. Childs Alan P. Warrington

With intensity-modulated radiotherapy (IMRT), it is important that the inverse planning process yields the most appropriate dose distribution for the patient and that the delivered dose then corresponds to the planned dose. This paper presents methods by which the inverse planning and delivery of segmental (step-and-shoot) IMRT can be verified, and gives results for a typical treatment planning...

Alireza Nikoofar Khadijeh Asnaashari Mahbobeh Nazarnejad, Mahdi Sadeghi Seied Rabi Mahdavi

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

Azizollah Rahimi Bijan Hashemi, Mohammad Hassan Zahmatkesh Ramin Jaberi Shahab Sheibani

Introduction: Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (LDR) Ir-192 wi...

Mahdi Jamali Mahdi Mommennezhad Shahrokh Naseri Tahereh yazdpour parizi

Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...

Journal: :journal of biomedical physics and engineering 0
k hadad shiraz university m zohrevand shiraz university r faghihi shiraz university a sedighi pashaki mahdieh m.r.i center, hamedan

background: hdr brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. in this method, depending on how advanced one tumor is, 2 to 6 gy dose as intracavitary brachytherapy is prescribed. due to high dose rate and tumor location, accuracy evaluation of treatment planning system (tps) is particularly important. common methods used in tps dosimetry are based on computat...

2011
Vicente ABELLA Rafael MIRÓ Belén JUSTE

MC treatment planning techniques provide a very accurate dose calculation compared to ‘conventional’ deterministic treatment planning systems. In the present work, PLanUNC (PLUNC), a set of software tools for radiotherapy treatment planning (RTP), is compared with MCNP5 (Monte Carlo N-Particle transport code) by calculating dose maps inside the RANDO phantom, utilized as the patient model, irra...

Journal: :iranian journal of medical physics 0
seyed mohsen hosseini daghigh radiation medicine department, shahid beheshti university, tehran, iran

introduction interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. the effect of applicator attenuation is not considered in dose calculation method released by aapm-tg43. in this study, the effect of high-dose rate (hdr) brachytherapy esophageal applicator on dose distribution was surveyed in hdr brachytherapy. materials and methods a cylindrical pmma phan...

2015
Gilles Moliner Françoise Izar Régis Ferrand Manuel Bardies Soléakhéna Ken Luc Simon

Intensity-modulated radiation therapy (IMRT) for total body irradiation (TBI) is practiced in several centers using the TomoTherapy System. In this context the planning target volume (PTV) is the entire body including the skin. A safety margin in the air surrounding the body should be added to take into account setup errors. But using inverse planning, over-fluence peak could be generated in th...

2014
W Ottosson C F Behrens

Bone, air passages, cavities, and lung are elements present in patients, but challenging to properly correct for in treatment planning dose calculations. Plastic scintillator detectors (PSDs) have proven to be well suited for dosimetry in non-reference conditions such as small fields. The objective of this study was to investigate the performance of a commercial treatment planning system (TPS) ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید