نتایج جستجو برای: nickel determination
تعداد نتایج: 284032 فیلتر نتایج به سال:
UV-induced carbonyl generation with formic acid is used for gaseous sample introduction into an atomic fluorescence spectrometer for the determination of ultra-trace nickel. Compared with conventional carbonyl generation, no toxic gas CO is involved in this work, and volatile Ni(CO)(4) is generated with a single reagent formic acid under the irradiation of UV light (253.7nm, 15W). The reaction ...
a method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-thiazolylazo)-p-cresol (tac) in micellar media of triton x-100 isproposed. the absorbance spectra were recorded in the range of 500 to 800 nm. the linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...
A spectrophotometric and first derivative spectrophotometric method was developed in aquatic Tween 80 micellar solutions for selective determination of nickel without using any pre-separation step. 1-(2-Pyridylazo)2-naphthol (PAN), as a sensitive chromogenic complexing agent formed a red-colored Ni(II)-PAN complex in Tween 80 media with satisfactory solubility and stability. Conditions such as ...
A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...
A new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0x10(-1)-5.0x10(-6) M with a lower limit of detection of 1.3x10(-6) M. It has a fast response time and can be used for a period o...
A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on the formation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 is proposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentration range for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.1...
A simple and new simultaneous fourth derivative spectrophotometric method is proposed for the analysis of a two-component system containing cobalt(II) and nickel(II) without separation using 2-hydroxy-3-methoxy benzaldehyde thiosemicarbazone (HMBATSC) as a chromophoric reagent. The reagent reacts with cobalt(II) and nickel(II) at pH 6.0, forming soluble brown and yellow colored species, respect...
A method for the determination of oxybiotin in the presence of biotin in biological materials has recently been described (1). This differential assay was based upon the stability of oxybiotin towards dilute potassium permanganate and the inactivation of biotin by t.his reagent. Thii paper describes another differential assay which is based on the contrasting behavior of biotin and oxybiotin to...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید