نتایج جستجو برای: nickel titanium

تعداد نتایج: 67800  

Journal: :iranian endodontic journal 0
faeze hamze assistant professor of operative dentistry, dental school, kerman university of medical sciences, kerman, iran kiamars honardar assistant professor of endodontics, shahed university of medical sciences, tehran, iran. kiumars nazarimoghadam associated professor of endodontics, shahed university of medical sciences, tehran, iran

introduction: root canal preparation is an important process in endodontic therapy. nickel-titanium (niti) rotary file system can be used in single length technique (simultaneous technique) without early coronal enlargement, as well as in crown-down method. the purpose of this in vitro study was to compare single length with crown-down methods’ shaping ability using mtwo niti files . materials ...

Journal: :journal of dental research, dental clinics, dental prospects 0
barat-ali ramazanzadeh department of orthodontics, school of dentistry, mashhad university of medical sciences, mashhad, iran farzaneh ahrari dental research center, mashhad university of medical sciences berahman sabzevari department of orthodontics, school of dentistry, rafsanjan university of medical sciences, rafsanjan, iran samaneh habibi

background and aims. this study aimed to investigate release of nickel ion from three types of nickel-titanium-based wires in the as-received state and after immersion in a simulated oral environment. materials and methods. forty specimens from each of the single-strand niti (rematitan “lite”), multi-strand niti (speed supercable) and copper niti (damon copper niti) were selected. twenty specim...

Journal: :American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics 2003
Vittorio Cacciafesta Maria Francesca Sfondrini Andrea Scribante Catherine Klersy Ferdinando Auricchio

The purpose of the study was to measure and compare the level of frictional resistance generated between conventional ceramic brackets (Transcend Series 6000, 3M Unitek, Monrovia, Calif), ceramic brackets with stainless steel slot (Clarity, 3M Unitek), conventional stainless steel brackets (Victory Series, 3M Unitek), and 3 different orthodontic wire alloys: stainless steel (stainless steel, SD...

2014
Gianluca Gambarini

instruments have been traditionally used with a continuous rotary motion, but more recently, a new approach to the use of nickel-titanium instruments in a reciprocating movement has been introduced by Yared (2004). The clockwise (CW) and counter-clockwise (CCW) rotations used by Yared were four-tenths and two-tenths of a circle respectively, and the rotational speed utilized was 400 rpm. The co...

2017
Kotryna Linauskienė Laura Malinauskienė Audra Blažienė

Background. Metals are very frequent sensitizers causing contact allergy and allergic contact dermatitis worldwide; up-to-date data based on patch test results has proved useful for the identification of a problem. Objectives. In this retrospective study prevalence of contact allergy to metals (nickel, chromium, palladium, gold, cobalt, and titanium) in Lithuania is analysed. Patients/Methods. ...

Journal: :iranian endodontic journal 0
narges farhad mollashahi eshagh ali saberi seyed rohollah havaei mohammad sabeti

introduction: root canal preparation techniques may cause postoperative pain. the aim of the present study was to compare the intensity of postoperative pain after endodontic treatment using hand files, single file rotary (oneshape), and single file reciprocating (reciproc) systems. methods and materials: in this single-blind, parallel-grouped randomized clinical trial a total of 150 healthy pa...

2014
Barat Ali Ramazanzadeh Farzaneh Ahrari Berahman Sabzevari Samaneh Habibi

Background and aims. This study aimed to investigate release of nickel ion from three types of nickel-titanium-based wires in the as-received state and after immersion in a simulated oral environment. Materials and methods. Forty specimens from each of the single-strand NiTi (Rematitan "Lite"), multi-strand NiTi (SPEED Supercable) and Copper NiTi (Damon Copper NiTi) were selected. Twenty specim...

Journal: :The Ulster Medical Journal 2003
K. J. Ho E. J. McAteer B. T. Little A. O'Brien

We report on the first case in Ireland of ureteric stenting with shape-memory alloy nickel-titanium (Memokath 051) stent in relieving malignant ureteric obstruction. Successful drainage was achieved and the patient required no further intervention indicating a clear place for these stents in the long-term management of malignant ureteric strictures. The use of ureteric double-J stenting in the ...

پایان نامه :وزارت بهداشت، درمان و آموزش پزشکی - دانشگاه علوم پزشکی و خدمات بهداشتی درمانی استان فارس - دانشکده دندانپزشکی 1384

چکیده ندارد.

2012
Anne Hahn Jutta Fuhlrott Anneke Loos Stephan Barcikowski

It is well-known that nanoparticles could cause toxic effects in cells. Alloy nanoparticles with yet unknown health risk may be released from cardiovascular implants made of Nickel-Titanium or Cobalt-Chromium due to abrasion or production failure. We show the bio-response of human primary endothelial and smooth muscle cells exposed to different concentrations of metal and alloy nanoparticles. N...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید