نتایج جستجو برای: out fracture

تعداد نتایج: 905455  

Journal: :Practica Oto-Rhino-Laryngologica 1980

2016
Bryce Diestelmeier Yuki Tochigi Nicole M. Grosland James Rudert

Recommended Citation Diestelmeier, Bryce. "Design and application of an instrumented pendulum device for measuring energy absorption during fracture insult in large animal joints in vivo.

2003
JOHN A. NAIRN

The properties of the fiber/matrix interface in composites have an influence on their overall performance. Common methods for studying the interface are micromechanical tests that load a single fiber/matrix interface to failure. Two popular tests are the microbond test [1] and the single-fiber, pull-out test [2]. In a microbond test a droplet of matrix is sheared off the fiber by pulling the fi...

Journal: :The Eurasian journal of medicine 2008
Esin Erbilen Harun Yuksel H Ibrahim Onder Murat Tunc Murat Kaya

The aim of this case report is to demonstrate that blow-out fractures can occur not only by a classical trauma mechanism but also from the consequences of a stick beat. A 66-year-old male was admitted to our hospital complaining of a sudden swelling of his right eyelid after blowing his nose. In his medical history there was the report of a hazel stick beat the previous day. Upon ophthalmologic...

2013
Ji Seon Cheon Bin Na Seo Jeong Yeol Yang Kyung Min Son

Retrobulbar hemorrhage, especially when associated with visual loss, is a rare but significant complication after facial bone reconstruction. In this article, two cases of retrobulbar hematoma after surgical repair of blow-out fracture are reported. In one patient, permanent loss of vision was involved, but with the other patient, we were able to prevent this by performing immediate decompressi...

2014
Seung-Hyun Rhee Tae-Seup Kim Jae-Min Song Sang-Hoon Shin Jae-Yeol Lee

PURPOSE This study assessed the association between eye symptoms (enophthalmos or diplopia) and site of damage, volume, deviated inferior rectus muscle (IRM) and type of fracture with computed tomography (CT). The intent is to anticipate the prognosis of orbital trauma at initial diagnosis. METHODS Forty-five patients were diagnosed with fractures of the inferior wall of one orbit. Fracture a...

2015
Eun Jun Jo Jong Hwan Kim Ho Jik Yang

BACKGROUND The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. METHODS A retrospective review was performed for all patients with ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید