نتایج جستجو برای: peak detector
تعداد نتایج: 198135 فیلتر نتایج به سال:
Terahertz detection capability of an n-type heterojunction interfacial work function internal photoemission (HEIWIP) detector is demonstrated. Threshold frequency, f0, of 3.2 THz (93 lm) was obtained by using n-type GaAs emitter doped to 1 · 10 cm 3 and Al0.04Ga0.96As single barrier structure. The detector shows a broad spectral response from 30 to 3.2 THz (10–93 lm) with peak responsivity of 6...
This paper attempts to improve the quality and the modification rate of a Stego Image. The input image provided for estimating the quality of an image and the modified rate is a bitmap image. The threshold value is used as a parameter for selecting the high frequency pixels from the Cover Image. The data embedding process are performed on the pixels that are found with the help of Threshold val...
In terms of quality control and for all quantitative analysis peak purity is a major task, which can be addressed in different ways. Often only peak shapes and chromatograms are taken into consideration but a very elegant possibility without the need to use a mass spectrometric detector is the comparison of spectra recorded with a diode-array detector during the registration of a chromatographi...
would be perfectly symmetrical with pronounced detector signal changes that clearly identify peak start and end.
In this work, oscillator strength and quantum efficiency of new spherical GaN/AlGaN quantum dot was investigated. In order to obtain these parameters, at first, Schrödinger equation is solved in GaN/AlGaN spherical coordinate system in effective mass approximation, and energy level, wave function and transition matrix element of the parameter are obtained. The results show that oscillator stre...
Typically, germanium detectors designed to have good sensitivity to low-energy photons and good efficiency at high energies are constructed from n-type crystals with a boron-implanted outer contact. These detectors usually exhibit inferior resolution and peak shape compared to ones made from p-type crystals. To overcome the resolution and peak-shape deficiencies, a new method of construction of...
• GEM10P4/CFG-PV4/DWR-30 Coaxial Detector System (Includes detector, cryostat, dewar, preamplifier, and 12-ft. cable pack); typical specifications: 10% relative efficiency, 1.75 keV resolution at 1.332 MeV, 41:1 peak-to-Compton ratio. • 659 0–5 keV Detector Bias Supply • 672 Spectroscopy Amplifier • 480 Pulser • C-24-12 Cables (2 ea.) • C-24-1 Cable • C-29 BNC Tee Connector • 4001A/4002D NIM Bi...
A recent Letter [1] revisits the problem of continuous weak measurement of quantum coherent oscillations of a qubit with a linear detector, the role of which is played by the quantum point contact (QPC) in the low-transparency regime. Previous studies of this problem [2–5] demonstrated that the qubit oscillations with the frequency should be reflected in the spectral density S ! of the detector...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید