نتایج جستجو برای: reactive power and load current harmonic

تعداد نتایج: 17000499  

2017
Abdeldjabbar Mohamed Kouadria Tayeb Allaoui

Conventional hysteresis current controllers have the disadvantage of a variable switching frequency. This paper proposes a fuzzy hysteresis band technique for the current control for shunt active power filter (SAPF). An active harmonic filter is used to eliminate current harmonics caused by nonlinear loads. The current control strategy utilizes using a selective Filter STF method to improve pow...

2011
Rodda Shobha Rani B. Jyothi

We proposed voltage-sourced converter (VSC) with Pulse-width modulation (PWM) provides a faster control that is required for flicker mitigation purpose. The voltage regulation in the distribution feeder is improved by installing a shunt compensator. The proposed DSTATCOM is modeled and its performance is simulated and verified for power factor correction and voltage regulation along with neutra...

2017
Satyanarayan Gorantla Goli Ravi Kumar

The paper presents the analysis of harmonic distortion when non-linear load is connected in different phases of power system with STATCOM for singly excited induction generator system with wind turbine as prime mover. Now-a-days due to the drastically increased in use of non linear loads causes many power quality problems in power system network. Those problems are classified as reactive power ...

2009
Marinko Stojkov Kruno Trupinić Srete Nikolovski

Usually, harmonics are the base point when engineers start to analyze waveform distortion. Frequencies of these voltage and current waveforms are integer multipliers of the base frequency of power system (50 Hz or 60 Hz). If it is not the case then these are named as intermediate harmonics. The sinusoidal waveforms of voltage characterize the ideal power system with the highest clarity of base ...

2015
Haiyan Wang

Large perceptual class motor load is the main production equipment of metallurgical enterprise, although has taken independent secondary substation power supply mode, but due to the influence of the impact load, Often appears on the bus voltage drop and low power factor and harmonic big problems, , this article is based on SVC compensation control mechanism, the sectional control mode, the prin...

Journal: :JCP 2010
Xiangzheng Xu Baichao Chen

This paper analyzes necessity of synthesis control of power quality aiming at characteristics of traction power supply system for electrified railway. According to the fact that the existing power quality control, the measure and means were introduced, analyzed and compared in detailed. From reliability, technology and economy point, the project of synthesis Control was put forward on power qua...

2001

With significant development of power converter technologies, there has been a rise of interest in an active power filter (AF). It is now well known that an active filter can easily compensate for harmonic current contents in the load current by inserting negative harmonics into the power network [B3]-[B10]. Basic principle of an active harmonic compensation is shown in Fig. 2.1. The AF can can...

2016
Vikas Kumar Chandra Mahendra Kumar Pradhan

In this work a new control strategy for simulation of three phase power filter for power quality improvement is used .This filter consists of shunt passive LC power filter and series active filter, with nonlinear and linear loads and also with variation in the source impedance. A new control method based on dual formulation of instantaneous reactive power vectorial theory is applied by consider...

Journal: :journal of ai and data mining 2015
r. ghanizadeh m. ebadian

this paper presents a new control method for a three-phase four-wire unified power quality conditioner (upqc) to deal with the problems of power quality under distortional and unbalanced load conditions. the proposed control approach is the combination of instantaneous power theory and synchronous reference frame (srf) theory which is optimized by using a self-tuning filter (stf) and without us...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

any change in the refractive index of a laser active medium can lead to serious degradation of beam quality, laser beam modes, laser performance and variation in the intensity distribution. alteration in the refractive index of laser active medium is especially notable in high power lasers. it is clear that in the laser beam production, the pumping agent induces a great amount of heat which...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید