نتایج جستجو برای: refrigerant 113

تعداد نتایج: 19377  

2014
R. L. Hall M. R. Johnson Madeleine R. Johnson

Madeleine R. Johnson AGMC/MAEL 813 Irving Wick Drive West Newark AFB, Ohio 43057-5149 This paper describes the initial results of a refrigerant retrofit project at the Aerospace Guidance and Metrology Center (AGMC) at Newark Air Force Base, Ohio. The objective is to convert selected types of test equipment to properly operate on hydrofluorocarbon (HFC) alternative refrigerants, having no ozone ...

2007
Cara Sanderson Cara Sanderson Martin Cara Martin Robert W. Sanderson

Title of Document: INVESTIGATION OF REFRIGERANT DISTRIBUTION IN A HOUSEHOLD REFRIGERATOR WITH A FOCUS ON THE ROLE OF THE ACCUMULATOR Cara Sanderson Martin, M.S. Mechanical Engineering, 2007 Directed By: Professor Reinhard Radermacher, Ph.D. Department of Mechanical Engineering In order to maximize household refrigerator performance, it is important to understand the basic relationship between e...

2016
Ze Zhang Rong Xue Shuangtao Chen Shijie Song Yu Hou

For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporat...

2014
Bin Gao Zhenhua Chen Qiang Gao

During the process of refrigerant alternative, R290 (propane), as a nature refrigerant used in Room Air Condition (RAC) system, is thought as a long-team substance and has attracted great attention. This paper simply introduced the characteristics and standard demands of R290 application, then, based on a 1HP R290 DC INV. RAC system at first, then finished the comparison test when a one-cylinde...

2015
Naeem Abas Rab Nawaz Nasrullah Khan

Modern lifestyle, industrialization and economy thrive on energy which is getting expensive overtime. Thermosyphon based systems are getting attraction for their promising heat transfer efficiency and zero energy utilization. Refrigerants having ozone depletion potential (ODP) and high Global Warming Potential (GWP) have been banned or under time bared permission under Montreal (1987) and Kyoto...

2014
Naotaka Hattori Hideto Nakao Tomoo Takayama

We have developed a new CO2 heat pump water heater compressor with a single rotary mechanism in practical use for the first time in the world. CO2 refrigerant doesn't destroy the ozone layer, and the global warming potential (GWP) is less than 1/1000 in comparison to hydro-fluorocarbon refrigerants. However the operating pressure of CO2 refrigerant is approximately three times as high as that o...

2014
J. D. Douglas E. A. Groll J. E. Braun Ray W. Herrick

According to the results of the international testing program AREP, the most likely replacements for HCFC-22 refrigerant will be blends of HFCs. However, as concerns about their global warming potential increase, other options should also be considered. As a naturally occurring substance, propane would be an ideal refrigerant, except for its flammability. When dealing with a flammable refrigera...

2014
Bin Li Steffen Peuker Andrew Alleyne Predrag S. Hrnjak Bin LI Steffen PEUKER Andrew ALLEYNE Predrag HRNJAK

Refrigerant mass migration and redistribution have been regarded as factors influencing the performance of air conditioning and refrigeration systems. This paper presents a dynamic model of an R134a automotive A/C system that is able to capture the shut-down and start-up cycling dynamics including the refrigerant mass migration transients. Building upon recent work (Li and Alleyne, 2010), the h...

2016
Jiangyan Liu Huanxin Chen Jiangyu Wang Guannan Li Haorong Li Wenju Hu Jiangyan LIU Huanxin CHEN Jiangyu WANG Guannan LI Haorong LI Wenju HU

Variable refrigerant flow (VRF) systems are easily subjected to performance degradation due to refrigerant leakage, mechanical failure or improper maintenance after years of operation. Ideal VRF systems should equip with fault detection and diagnosis (FDD) program to sustain its normal operation. This paper presents the fault diagnosis method for refrigerant charge faults of variable refrigeran...

2014
Santanu Prasad Datta Prasanta Kumar Das Siddhartha Mukhopadhyay Santanu P. DATTA Prasanta K. DAS Siddhartha MUKHOPADHYAY

Using identical mechanical hardware used in an automobile, a stationary test bench has been developed for an automotive air conditioning system (AACS). However, a number of additional sensors have been used in the system for an accurate assessment of its performance. The steady state performance of the system has been investigated for three independent variables, namely the refrigerant charge l...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید