نتایج جستجو برای: screw removal

تعداد نتایج: 157088  

Journal: :Journal of Orthopaedic Science 2014

2010
Xinning Li Michael J Heffernan Christina Kane Walter Leclair

Hip fractures are a common injury among the elderly. Internal fixation with an intramedullary (IM) system has gained popularity for the treatment of intertrochanteric femur fractures. Multiple complications associated with IM fracture fixation have been described, however, we report a rare complication of medial pelvic migration of the lag screw of a short IM nail in a stable construct ten week...

Journal: :The Journal of bone and joint surgery. British volume 2009
N Hamid B J Loeffler W Braddy J F Kellam B E Cohen M J Bosse

The purpose of this study was to compare the clinical and radiological outcome of patients with intact, broken and removed syndesmosis screws after Weber B or C ankle fracture with an associated injury to the syndesmosis. We hypothesised that there would be no difference. Of a possible 142 patients who fulfilled our inclusion criteria, 52 returned for clinical and radiological assessment at lea...

2011
Felipe Miguel SALIBA Mayra CARDOSO Marcelo Ferreira TORRES Alexandre Carvalho TEIXEIRA Eduardo José Veras LOURENÇO Daniel de Moraes TELLES

OBJECTIVES Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in the loosening of the screws. The pres...

2015
Harpreet Singh Rohit Sharma Sachin Gupta Narinderjit Singh Simarpreet Singh

INTRODUCTION The advent of locking plates has brought new problems in implant removal. Difficulty in removing screws from a locking plate is well-known. These difficulties include cold welding between the screw head and locking screw hole, stripping of the recess of the screw head for the screwdriver, and cross-threading between threads in the screw head and screw hole. However, there are cases...

Journal: :The Journal of craniofacial surgery 2015
Rodrigo Fariña Andrés Hinojosa Martín Sánchez Sergio Olate

There are 2 types of distraction devices for mandibular distraction: buried and external. The advantage of buried devices is the stability, but the difficulty in removing the screws is the greatest disadvantage. To resolve this problem, an osteosynthesis screw (Fariña Screw) has been designed, which greatly facilitates its removal when buried distractors are used.

Journal: :The Journal of hand surgery, European volume 2011
J M Cognet M Levadoux X Martinache

Seven patients with chronic scapholunate instability (Geissler grade 2-4) were treated by percutaneous placement of screws across the scapholunate joint after arthroscopic debridement of the remnants of the scapholunate ligament. In all seven cases, the screw caused partial destruction of the lunate and/or scaphoid requiring screw removal within 6 months. We no longer perform this procedure.

2015
Brooke Crawford Christopher Lenarz J. Tracy Watson Dirk Alander

Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwe...

2015
Direk Tantigate Kongkhet Riansuwan Banchong Mahaisavariya Kitichai Sukjaitham

A broken lag screw of the cephalomedullary nail is a rare condition. Removal of the retained lag screw from the femoral head is also very challenging. This article describes a surgical technique and the modified instrument that was available in the operating room for removing the broken implant by closed technique.

Journal: :Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association 2000
B R Bach

Interference screws are frequently used for fixation of anterior cruciate ligament grafts. When revision surgery is necessary, it is important for the surgeon to recognize variations in interference screw morphology to reduce the potential difficulties in screw removal. The purpose of this observational study is to review the variety of metallic and nonmetallic absorbable interference screws co...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید