نتایج جستجو برای: silica coated hydroxyapatite

تعداد نتایج: 91804  

2011
Gurbhinder Singh Surendra Singh Satya Prakash

It has been reported by previous research work that in plasma spray process hydroxyapatite decomposes into some amorphous phases due to rapid cooling of the coated substrate during the coating process, which causes instability of coated implant. Post coating heat treatment has been expected to minimize these phases and also enhance the long term reliability of hydroxyapatite coatings on metal s...

Journal: :Analytical chemistry 2000
Chang Her

A simple procedure was developed for preparing a carbon-coated fused-silica capillary for use in sheathless capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The tapered capillary tip was smeared with a marker pen before coating with carbon using a soft pencil. The layer from the ink of the marker pen was critical to the preparation of the carbon-coated capillary. The fabric...

2011
Manoj Mittal S. K. Nath Satya Prakash

In order to increase the bone bioactivity of metallic implants, hydroxyapatite (HA: Ca10(PO4)2(OH)6) is often coated on their surface so that real bond with surrounding bone tissue can be formed. In present study, HA coatings were deposited on AISI 316L SS and titanium using shrouded plasma spray process. The coated specimens were subjected to X-ray diffraction (XRD) analysis, field emission sc...

Journal: :The Journal of bone and joint surgery. British volume 2007
J Uvehammer J Kärrholm L Carlsson

We have carried out a radiostereometric study of 50 patients (54 knees) with osteoarthritis of the knee who were randomly allocated to receive a cemented or a hydroxyapatite-coated femoral component for total knee replacement. The patients were also stratified to receive one of three types of articulating surface (standard, rotating platform, Freeman-Samuelson (FS)1000) all based on the Freeman...

Journal: :The journal of international advanced otology 2016
Beldan Polat Mete İşeri Kadir Serkan Orhan Ayça Başkadem Yılmazer Necati Enver Didem Ceylan Ahmet Kara Yahya Güldiken Şenol Çomoğlu

OBJECTIVE To compare two different percutaneous bone-anchored hearing aid (BAHA) abutment systems regarding operation time, scar healing, quality of life, implant stability, audiologic results, and complications. MATERIALS AND METHODS The study involves a prospective multi-center clinical evaluation. Thirty-two consecutive patients who had undergone BAHA surgery from January 2011 to January 2...

Journal: :Bulletin (Hospital for Joint Diseases (New York, N.Y.)) 2001
G Kirsh M Roffman M Kligman

Prospective review examined 69 patients aged over 65 years (mean: 73 years; range: 65 to 85 years) who underwent 72 primary hydroxyapatite-coated total hip replacements by one surgeon. The femoral component used was titanium alloy coated by hydroxyapatite on the proximal third and the acetabular component was spherical and unthreaded, coated with hydroxyapatite. All patients were evaluated clin...

Journal: :Bone 2010
Anna Kajsa Harding Sören Toksvig-Larsen Magnus Tägil Annette W-Dahl

INTRODUCTION Bisphosphonates have been shown to reduce osteoclastic activity and enhance pin fixation in both experimental and clinical studies. In this prospective, randomized study of high tibial osteotomy using the hemicallotasis (HCO) technique, we evaluate whether treatment by one single infusion of zoledronic acid can enhance the pin fixation. MATERIALS AND METHODS 46 consecutive patien...

2014
Dennis Mathew Garima Bhardwaj Qi Wang Linlin Sun Batur Ercan Manisavagam Geetha Thomas J Webster

BACKGROUND Plasma-spray deposition of hydroxyapatite on titanium (Ti) has proven to be a suboptimal solution to improve orthopedic-implant success rates, as demonstrated by the increasing number of orthopedic revision surgeries due to infection, implant loosening, and a myriad of other reasons. This could be in part due to the high heat involved during plasma-spray deposition, which significant...

Journal: :The West Indian medical journal 2005
A Simunek D Kopecka M Cierny I Krulichova

BACKGROUND The effect of hydroxyapatite coating of dental implants is controversial. The long-term fate of hydroxyapatite-coated implants has been the subject of some criticism. PURPOSE The aim of this retrospective study was to assess the clinical outcome of hydroxyapatite-coated cylindrical root-form endosseous Impladent dental implants (LASAK Ltd, Prague, Czech Republic) during a six-year ...

Journal: :Dental materials journal 2008
Goro Nishigawa Yukinori Maruo Masao Irie Morihiko Oka Kumiko Yoshihara Shogo Minagi Noriyuki Nagaoka Yasuhiro Yoshida Kazuomi Suzuki

The purpose of this study was to evaluate how ultrasonic cleaning of silica-coated zirconia surfaces would influence the latter's bond strength to resin luting material. Forty zirconia specimens were divided into four groups: one air abrasion group and three silica-coated groups. Silica-coated specimens were cleaned with distilled water using an ultrasonic cleaner after tribochemical silica coa...