نتایج جستجو برای: slab head phantom
تعداد نتایج: 193829 فیلتر نتایج به سال:
Reconstruction algorithms for imaging fluorescence in near infrared ranges usually normalize fluorescence light with respect to excitation light. Using this approach, we investigated the influence of absorption and scattering heterogeneities on quantification accuracy when assuming a homogeneous model and explored possible reconstruction improvements by using a heterogeneous model. To do so, we...
PURPOSE To propose a method to reduce the slab boundary artifacts in three-dimensional multislab diffusion MRI. METHODS Bloch simulation is used to investigate the effects of multiple factors on slab boundary artifacts, including characterization of residual errors on diffusion quantification. A nonlinear inversion method is proposed to simultaneously estimate the slab profile and the underly...
A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racetrack microtron. Source distributions for the Monte Carlo calculations were rec...
introduction low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. dosimetric characteristics of a new irseed 125i brachytherapy source have been determined using the lif thermoluminescent dosimeter (tld) chips. materials and methods dose rate constant, radial dose function, and anisotropy function around the irseed 125i so...
The quality of images obtained from cone-beam computed tomography (CBCT) is important in diagnosis and treatment planning for dental and maxillofacial applications. However, X-ray scattering inside a human head is one of the main factors that cause a drop in image quality, especially in the CBCT system with a wide-angle cone-beam X-ray source and a large area detector. In this study, the X-ray ...
Background & Objectives: Computed tomography (CT) represents 11% of all diagnostic radiology procedures but it contributes to almost 67% of the total effective dose to the human population. In head and neck CT which consist of 1/3 of total CT scans, other critical organs such as lenses and thyroid are in the radiation field. Also in the abdomen and pelvis scan, irradiation of ovaries is unavoid...
INTRODUCTION Wide agreement has been reached among the main Bodies and Organizations involved in standardization of radiation protection to define as operational quantity for individual monitoring of external exposure, the personal dose equivalent, Hp(d) (1,2,3). However, as Hp(d) is defined in the human body, it is not a measurable quantity. In practice, it has to be estimated from the indicat...
In this paper, properties of slab deformation in sizing press mill as one of the slab reduction processes in hot rolling mills have been evaluated using the elastoviscoplastic finite element method with explicit formulation. Effect of prarameters such as initial slab width and thickness, reduction, feed pitch, and anvil speed on factors such as dogbone formation, head and tail fishtail profile,...
A new grid-based Boltzmann equation solver, Acuros, was developed specifically for performing accurate and rapid radiotherapy dose calculations. In this study we benchmarked its performance against Monte Carlo for 6 and 18 MV photon beams in heterogeneous media. Acuros solves the coupled Boltzmann transport equations for neutral and charged particles on a locally adaptive Cartesian grid. The Ac...
background: radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. the scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (mird) method. at the end, the results of mird calculations were compared with thermoluminescent dosimeter (tld-100). ma...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید