نتایج جستجو برای: solid phase spectrophotometry

تعداد نتایج: 761767  

Journal: :international journal of environmental research 0
h. sid kalal nuclear fuel cycle school, nuclear science and technology research institute, aeoi, p.o.box 11365-3486, tehran, iran h. hoveidi graduate faculty of environment, university of tehran, p.o. box 14155-6135, tehran, iran m. thagiof nuclear fuel cycle school, nuclear science and technology research institute, aeoi, p.o.box 11365-3486, tehran, iran n. pakizevand nuclear fuel cycle school, nuclear science and technology research institute, aeoi, p.o.box 11365-3486, tehran, iran m.r. almasian nuclear fuel cycle school, nuclear science and technology research institute, aeoi, p.o.box 11365-3486, tehran, iran m.a. firoozzare nuclear fuel cycle school, nuclear science and technology research institute, aeoi, p.o.box 11365-3486, tehran, iran

a chelating resin is prepared by condensation polymerization of aniline with formaldehyde andcharacterized by ft-ir, elemental analysis and studied for the preconcentration and determination of traceplatinum ion from environmental water sample using inductively coupled plasma-atomic emission spectroscopy(icp-aes). the optimum ph value for sorption of the metal ions was 5. the maximum adsorption...

Journal: :international journal of environmental research 0

styrene is an important constituent of widely used organic solvents in industries for production of various synthetic materials. the use of solid-phase extraction (spe) has grown and is a fertile technique of sample preparation as it provides better results than those produced by liquidliquid extraction. in this study, spe has been optimized, regarding sample ph, sample concentration, sample fl...

2017
Maria A. Morosanova Elena I. Morosanova

BACKGROUND Ascorbic acid is one of the most important vitamins to monitor in dietary sources (juices and vitamins) and biological liquids. RESULTS Silica and silica-titania xerogels doped with Mo,P-heteropoly compounds (HPC) have been synthesized varying titanium(IV) and HPC content in sol. Their surface area and porosity have been studied with nitrogen adsorption and scanning electron micros...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2010
Sayed Zia Mohammadi Daryoush Afzali Yar Mohammad Baghelani

In the present work, a new ligandless-ultrasound-assisted emulsification microextraction (LL-USAEME) method was developed for preconcentration trace amounts of nickel as a prior step to its determination by flame atomic absorption spectrometry. Some factors influencing the extraction efficiency of nickel and its subsequent determination were studied and optimized, such as type and volume of the...

2014
J. Álvarez Méndez C. Gutiérrez Lovera J. Barciela García R. M. Peña Crecente S. García Martín C. Herrero Latorre

New materials have significant impact on development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes (SWCNTs and MWCNTs) -due to their high adsorption and desorption capacitieshave been employed as sorption substrates in solid-phase extraction for the preconcentration of heavy metals from diverse ...

Journal: :iranian journal of analytical chemistry 2014
sandeep jaggi usha gupta

a simple and sensitive method has been developed for the preconcentration and determination of trace level of co(ii) using uv-vis spectrophotometry. β-cyclodextrin polymer modified with 1-(2-pyridylazo)-2-naphthol (pan) is used for the preconcentration of co(ii) from samples at ph 8.5. the polymer is synthesized and characterized using elemental analysis, ft-ir and sem analysis. the factors aff...

2012
MOHD NASIR TAIB

Conventional matrix characterization by visible spectrophotometry technique required sample destruction and limited to drug content assay. This study investigated the capacity of visible spectrophotometry technique to characterize both drug content and molecular characteristics of solid nifedipine-hydroxypropylmethylcellulose films stored at 25 and 50 % relative humidities in their intact form....

Journal: :journal of chemical health risks 0
saeedeh ansari department of chemistry, islamic azad university, saveh branch, saveh, iran azam ghorbani department of chemistry, islamic azad university, saveh branch, saveh, iran

in this study, for the analysis of human urine samples, a novel method explained for the determination of celecoxib, a nonsteroidal anti-inflammatory drug (nsaid), using molecularly imprinted solid-phase extraction (mispe) coupled with high-performance liquid chromatography (hplc). the synthesis of the mip was performed by precipitation polymerization in methacrylic acid (maa), ethylene glycol ...

Journal: :مجله دانشگاه علوم پزشکی قم 0
حمیدرضا حیدری hr heidari qom university of medical sciencesدانشگاه علوم پزشکی قم سید جمال الدین شاه طاهری sj shahtaheri tehran university of medical sciencesدانشگاه علوم پزشکی تهران محمود علیمحمدی m alimohammadi tehran university of medical sciencesدانشگاه علوم پزشکی تهران عباس رحیمی فروشانی a rahimi-froshani tehran university of medical sciencesدانشگاه علوم پزشکی تهران فریده گلبابایی f golbabaei tehran university of medical sciencesدانشگاه علوم پزشکی تهران

background and objectives: analytical methods for volatile organic compounds (vocs) in different samples need extraction of compounds, by applying hazardous solvents. solid phase micro-extraction (spme) is a solvent-free equilibrium extraction method, in which proper calibration can allow quantitative determinations of vocs at a very good sensitivity without the use of any organic solvent. vocs...

Journal: :iranian journal of public health 0
hr heidari dept. of occupational health sj shahtaheri dept. of occupational health, center for environmental research m alimohammadi dept .of environmental health a rahimi-froshani dept. of epidemiology and biostatistics, school of public health, tehran university of medical scien

background: determination of organic pollutants usually requires extraction of the pollutants from samples, using hazard­ous solvent. solid phase micro-extraction (spme) is a solvent-free equilibrium extraction method, in which, proper calibra­tion can allow quantitative measurements of organic pollutants at a very good sensitivity without the use of any organic sol­vent. because individual voc...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید