نتایج جستجو برای: sp34 slab phantom
تعداد نتایج: 27243 فیلتر نتایج به سال:
IMRT often requires delivering small fields which may suffer from electronic disequilibrium effects. The presence of heterogeneities, particularly low-density tissues in patients, complicates such situations. In this study, we report on verification of the DPM MC code for IMRT treatment planning in heterogeneous media, using a previously developed model of the Varian 120-leaf MLC. The purpose o...
INTRODUCTION A sweeping beam technique for total body irradiation in standard treatment rooms and for standard linear accelerators (linacs) is introduced, which does not require any accessory attached to the linac. Lung shielding is facilitated to reduce the risk of pulmonary toxicity. Additionally, the applicability of a commercial radiotherapy planning system (RTPS) is examined. MATERIAL AN...
Purpose: The experimental verification of the Acuros XB (AXB) algorithm was conducted in a heterogeneous rectangular slab phantom, and compared to the Anisotropic Analytical Algorithm (AAA). The dosimetric impact of the AXB for stereotactic body radiation therapy (SBRT) and RapidArc planning for 16 non-small-cell lung cancer (NSCLC) patients was assessed due to the dose recalculation from the A...
Although there are many works on evaluating dose calculations of the anisotropic analytical algorithm (AAA) using various homogeneous and heterogeneous phantoms, related work concerning dosimetry due to tangential photon beam is lacking. In this study, dosimetry predicted by the AAA and collapsed cone convolution (CCC) algorithm was evaluated using the tangential photon beam and phantom geometr...
introduction: multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. in this work, we investigated mr-based magic gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. materials and methods: a heterogeneous slab phantom including bones was made....
The water phantom is used for LINAC calibration to measure absorbed dose radiation. Practically, it requires a long preparation time and considered less efficient. To increase efficiency, the medical physics team in hospital uses slab as tool. Consequently, correction factor crucial define equivalence of doses resulted from phantom. measurement was performed according IAEA TRS-398 dosimetry pro...
A model has been developed based on random walk theory that allows the diffusion of light along a principal axis to differ from that in orthogonal directions. We present expressions that describe the time-resolved intensity measured across a slab and on the surface of a semi-infinite medium for a principal axis oriented parallel or perpendicular to the surface. The model of time-resolved transm...
Therapeutic treatment plan evaluation is often based on examining the radiotherapy treatment planning (RTP) system dose distributions in the target and surrounding normal structures. To study the effects of tissue inhomogeneities on photon dose distributions, we compared FOCUS RTP system dose distributions from the measurement-based Clarkson and model-based MultiGrid Superposition (MGS) algorit...
BACKGROUND Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the targe...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید