نتایج جستجو برای: stress shielding

تعداد نتایج: 447020  

Journal: :Clinical orthopaedics and related research 1992
R Huiskes H Weinans B van Rietbergen

Bone resorption around hip stems is a disturbing phenomenon, although its clinical significance and its eventual effects on replacement longevity are as yet uncertain. The relationship between implant flexibility and the extent of bone loss, frequently established in clinical patient series and animal experiments, does suggest that the changes in bone morphology are an effect of stress shieldin...

2012
Chang Wook Han Ick Hwan Yang Hye Yeon Lee Chang Dong Han

PURPOSE We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. MATERIALS AND METHODS One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems ...

2017
Lennert de Ruiter Dennis Janssen Adam Briscoe Nico Verdonschot

The current study was designed to investigate the mechanical response of a polyetheretherketone-on-polyethylene total knee replacement device during a deep squat. Application of this high-demand loading condition can identify weaknesses of the polyetheretherketone relative to cobalt-chromium. This study investigated whether the implant is strong enough for this type of loading, whether cement s...

Journal: :jentashapir journal of health research 0
vahid karami department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran mansour zabihzadeh department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of radiotherapy and radiation oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, 61357-33118, ahvaz, ir iran. tel: +98-9125032283, fax: +98-6133332066 mehrdad gholami department of medical physics, school of para medicine sciences, lorestan university of medical sciences, khorramabad, ir iran

conclusions comprehensive protection programs with on-the-job training courses for staff members are strongly recommended, as well as, the provision of radiological shields and gonad shielding protocols in radiology departments to reduce the patient’s radiation dose during radiological examinations. materials and methods a retrospective, observational cross-sectional study on the application of...

2014
Ching-Lung Tai Yung-Chou Chen Pang-Hsin Hsieh

BACKGROUND Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narrowing of the femoral neck has often been found, which may lead to fracture. This phenomenon has bee...

2014
Chun-Ming Chen Wen-Chi Tsai Shang-Chih Lin Ching-Shiow Tseng

BACKGROUND Despite improvements in shape, material, and coating for hip stem, both stress shielding and aseptic loosening have been the major drawbacks of stemmed hip arthroplasty. Some nonstemmed systems were developed to avoid rasping off the intramedullary canal and evacuating the bone marrow due to stem insertion. METHODS In this study, the finite-element models of one intact, one stemmed...

Journal: :Nano letters 2015
Sandeep Kumar David M Parks

Mechanical failure of an ideal crystal is dictated either by an elastic instability or a soft-mode instability. Previous interpretations of nanoindentation experiments on suspended graphene sheets,1,2 however, indicate an anomaly: the inferred strain in the graphene sheet directly beneath the diamond indenter at the measured failure load is anomalously large compared to the fracture strains pre...

2017
Abdellah Ait Moussa Justin Fischer Rohan Yadav Morshed Khandaker

The average life expectancy of many people undergoing total hip replacement (THR) exceeds twenty-five years and the demand for implants that increase the load-bearing capability of the bone without affecting the short- or long-term stability of the prosthesis is high. Mechanical failure owing to cement damage and stress shielding of the bone are the main factors affecting the long-term survival...

Journal: :The Journal of bone and joint surgery. British volume 1997
G H Van Lenthe M C de Waal Malefijt R Huiskes

Inadequate bone stock is often found in revision surgery of femoral components of total knee replacements. Our aim was to test the hypothesis that these remodelling patterns can be explained by stress shielding, and that prosthetic bonding characteristics affect maintenance of bone mass. We made a three-dimensional finite-element model of an average male femur with a cemented femoral knee compo...

Journal: :The Journal of bone and joint surgery. British volume 2006
U G Leichtle C I Leichtle B Schmidt F Martini

Peri-prosthetic bone loss caused by stress shielding may be associated with aseptic loosening of femoral components. In order to increase primary stability and to reduce stress shielding, a three-dimensional, cementless individual femoral (Evolution K) component was manufactured using pre-operative CT scans. Using dual energy x-ray absorptiometry, peri-prosthetic bone density was measured in 43...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید