نتایج جستجو برای: switching overvoltage

تعداد نتایج: 72474  

2013
Zhengqing Han Donglin Zhang Yuning Wu Shibin Gao

With the application of the articulated phase insulator, and the speed of electric locomotive rising, it is inevitable for the electric locomotive to adopt the technology automatic passing through the electric phase separation. However, when the locomotive passes the electric phase separation, a variety of overvoltages will be generated, such as the cut-off overvoltage and the closing overvolta...

Journal: :International Journal of Power Electronics and Drive Systems 2022

<span lang="EN-US">The proposed scheme is employed for the efficient operation of a DC-DC-based buck converter. This protection shows optimal placement varistor in power electronics converter side under different surge conditions. Advanced varistors have excellent electrical material properties and electrothermal behavior enhancement absorption capability. Varistors been examined widely l...

2014
Bo Ye Ming Li Biao Bai Gefei Qiu

When the ultra high voltage (UHV) substation used the gas insulated switchgear (GIS) system to switch lines with capacitive current, the pre-breakdown and multiple reignition will occur between switching contacts. Because of discharge characteristics of SF6 and special structures of GIS system, the variations of the electromagnetic transient process and very fast transient overvoltage (VFTO) ar...

2014
Hongtao Zeng Linlin Lin Zhixin Wang Wengang Tian Cong Feng Zhihuai Xiao

500kV substation is especially important to the grid of our country, once it encounters lightning damage, the safety and reliability of the whole power system will be directly affected. As lightning intruding waves will cause overvoltage on electric equipments by intruding from the transmission line or straightly stroking the substation, which seriously influences the insulation level of equipm...

2017
Li Zhang Shengwei Fang Guozheng Wang Tong Zhao Liang Zou

In recent years, with the rapid development of offshore wind turbines (WTs), the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs, the influencing factors and the response rules of transient overvoltage are analyzed. In this paper, a new integrated electromagnetic transient m...

Journal: :DEStech Transactions on Environment, Energy and Earth Sciences 2018

2016
Steven Xie

The challenge of designing robust electronic circuitry often results in a design with a multitude of discrete protection components with associated cost, design time, and space additions. This article discusses fault protected switch architecture, along with the performance benefits and other advantages it offers vs. traditional discrete protection solutions. A new novel switch architecture and...

2015
Stjepan Jonjić Zoran Baus Marinko Barukčić

Abstract – This paper investigates overvoltages on the SF6 substation enclosure caused by the switching operation of the interrupter. The paper analyzes the amplitude and the overvoltage duration on the substation enclosure. Switching overvoltages take part in the everyday drive of HV substations and constitute an undesired phenomenon that may often, beside transient disturbances, lead to undes...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید