An evaluation of two anthropomorphic breast phantoms, which have been designed for quality assurance and dose verification of radiotherapy treatment of breast cancer patients, is presented. These phantoms are identical in terms of their dimensions and shape, and composed of several layers of either Plastic Water or tissue-equivalent material. Both water- and tissue-equivalent phantoms include l...
Aim: The present study is devoted to evaluate the dose at different points defined on the patient using semiconducting diodes and thermoluminescence detectors to excute verification of the dose at these relevant points calculated by means of movement couch and Beam Zones method of the Total Body Irradiation Technique. Material and Method: In this technique; 11 patients using 6 MV X-ray in the (...
The linearity of thermoluminescence (TL) dose response curve, in low dose levels, is affected by background signals appearing at the tail of the glow curves. The effects of these signals also restrict the use of the high temperature glow peaks in many applications. In this study, a new reading out procedure was presented to reduce the background signals and increase the resolution of the high t...
Nowadays, radiography is a necessary procedure in diagnosis and treatment of patients with dental problems. According to the ALARA (as low as reasonably achievable) principle, dentists must take radiographs of sufficient quality at the lowest possible radiation dose to the patients. The assessment of patient dose on panoramic radiography is difficult because of dynamic nature of the imaging pro...
The European Directive 96/29/EURATOM and adapted national regulations on radiation protection are claiming new limits of radiation exposure and the introduction of new measuring quantities. Dosimeters for area monitoring of penetrating X-ray and gamma radiation have to measure the ICRU operational quantity ambient dose equivalent, H*(10). In this paper, the development stages of a passive H*(10...
The commonly used thermoluminescent dosimeter TLD-100 (Harshaw Chemical Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high-energy therapies. As a result, TLD-100 measurements outside of the treatment field are suspect when high-energy radiation is used. Although alternatives such as TLD-700 do not respond to neutrons, specialty dos...
PURPOSE To design, construct, and evaluate an anthropomorphic phantom for evaluation of intensity-modulated radiation therapy (IMRT) dose planning and delivery, for protocols developed by the Radiation Therapy Oncology Group (RTOG) and other cooperative groups. METHODS AND MATERIALS The phantom was constructed from a plastic head-shaped shell and water-equivalent plastics. Internal structures...
In preparing of thermoluminescent dosimeters (TLD) it is common to use as agglutinator the polytetrafluoroethylene (PTFE), called Teflon. In this paper the physical, morphological and dosimetric characteristics of Teflon were evaluated aiming its application in thermoluminescent dosimetry. The differential thermal analysis (DTA) and thermogravimetry (TG) results showed that the Teflon glass tra...